2010-06-21 18:21:03 | ****CORRECTIONS**** |
| ****DCA MODEL FMT2356A***MFGR MODEL FERN (BAYBERRY)*** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2007 |
| FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| |
| 1. FBC R408.2, SPECIFY VENTILATION OPENING SIZE TO SHOW |
| COMPLIANCE WITH THE FBC REQUIREMENT. |
| |
| 2. ACCESS IS SHOWN UNDER THE PORCH. ENGINEER'S NOTE |
| STATES THAT ACCESS IS NOT TO BE LOCATED UNDER THE |
| PORCH. THIS LOCATION PROHIBITS ACCESS TO THE OTHER |
| SECTION OF CRAWL SPACE. PROVIDE ACCESS TO ALL AREAS OF |
| THE CRAWL SPACE FBC408.2. |
| |
| 3. SK3 EXTERIOR STEM WALL SHOWS 8" MIN FROM GRADE TO |
| BOTTOM OF FLOOR. SEE FBC R408.4, IF EXTERIOR GRADE IS |
| AT 8", AN ACCESS AREA COMPLYING WITH FBC R408.4 SHALL |
| BE PROVIDED. IN ORDER TO AVOID FIELD ISSUES, IT IS |
| SUGGESTED THAT A DETAIL OR SPECIFICATION WITH SPECIFIC |
| REQUIREMENTS BE PROVIDED. |
| |
| |
| |
| THE FOLLOWING DOES NOT NEED TO BE ADDRESSED, AVISORY |
| ONLY: |
| |
| AFTER ISSUANCE OF THE MASTER, SITE PERMITS WILL |
| REQUIRE: |
| |
| 1. SOILS INVESTIGATION REPORT, 2000 PSF BEARING MINIMUM |
| 2. CURRENT SURVEY |
| 3. SITE PLAN SHOWING PROPOSED LOCATION (ZONING REVIEW |
| REQUIRED) |
| 4. PROPOSED FINISHED FLOOR ELEVATION FBC403.1.7.3. |
| 5. STAIR OR DOOR LANDING DETAIL |
| 6. DETAIL FOR STRUCTURAL CONNECTION BETWEEN MODULES |
| 7 SEPARATE PERMITS FOR ELECTRIC HOOKUP, PLUMBING |
| HOOKUP, MECHANICAL, IMPACT PROTECTION, ROOF |
| 8. SITE SPECIFIC ENERGY CALCS REQUIRED |
| 9. IMPACT FEE ASSESSMENT - PLANS ARE TO BE STAMPED AND |
| THE RECEIPT ATTACHED TO APPLICATION |
| |
| |
| |
| |
| |