Plan Review Notes For Permit 10050567 |
Permit Number |
10050567 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2010-05-19 15:27:51 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | DCA RULE 9B-72 FOR FLAT ROOF SYSTEM TO BE INSTALLED. | | NONE WAS SUBMITTED FOR REVIEW. | | | | 2- CLEARLY IDENTIFY WHICH APPROVED FLAT ROOF ASSEMBLY | | AND BASE SHEET FASTENING OPTION ARE GOING TO BE | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL | | CODE. | | | | 3- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | LIMITATION #7 ON LAST PAGE OF NOA TO BE SUBMITTED. | | ***NOTE: APPROVED ASSEMBLIES THAT ARE LIMITED BY | | GENERAL LIMITATION #9 CAN'T BE USED IN THIS AREA | | BECAUSE THEY DON'T MEET THE DESIGN PRESSURES REQUIRED | | BY SEC. R301. | | | | 4- IF GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | SUBMITTED REQUIRES SIGNED AND SEALED RAS 117 | | CALCULATIONS, THEN SINGED AND SEALED RAS 117 | | CALCULATIONS ARE REQUIRED. | | | | JULIO GOMEZ | | COMMERCIAL PLANS EXAMINER | | (561)805-6712 | | |
|