2010-05-19 15:27:51RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR FLAT ROOF SYSTEM TO BE INSTALLED.
 NONE WAS SUBMITTED FOR REVIEW.
  
 2- CLEARLY IDENTIFY WHICH APPROVED FLAT ROOF ASSEMBLY
 AND BASE SHEET FASTENING OPTION ARE GOING TO BE
 INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL
 CODE.
  
 3- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA TO BE SUBMITTED.
 ***NOTE: APPROVED ASSEMBLIES THAT ARE LIMITED BY
 GENERAL LIMITATION #9 CAN'T BE USED IN THIS AREA
 BECAUSE THEY DON'T MEET THE DESIGN PRESSURES REQUIRED
 BY SEC. R301.
  
 4- IF GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 SUBMITTED REQUIRES SIGNED AND SEALED RAS 117
 CALCULATIONS, THEN SINGED AND SEALED RAS 117
 CALCULATIONS ARE REQUIRED.
  