2010-07-26 12:57:32 | BUILDING PLAN REVIEW |
| PERMIT: 10040281 |
| ADD:720 N TAMARIND AVE |
| CONT: TO BE DETERMINED |
| TEL: (561)644-7416 JEFF HALVERSON |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 3RD REVIEW |
| JULY 269/2010 |
| ACTION: DENIED |
| |
| 1A) SHEET G-101, A-001 DEMOLITION & SITE PLAN A-002 |
| INDICATE THERE TO BE WORK ON MULTIPLE LOTS, A UNITITY |
| OF TITLE WILL BE REQUIRED. UNITY OF TITLE. THE PROPOSED |
| BUILDING STRUCTURE TRANSGRESSES LEGAL BOUNDARY LINES |
| BETWEEN THE LOTS WHICH COMBINE TO FORM 'THE SITE'. A |
| 'UNITY OF TITLE' SHALL BE RECORDED AT THE COUNTY |
| COURTHOUSE. SUBMIT A COPY OF THE RECORDED 'UNITY OF OF |
| TITLE' DOCUMENT SO THAT FBC TABLE 601 BOUNDARY LINE |
| REQUIREMENTS MAY BE DEEMED NOT APPLICABLE. |
| |
| 1B) SEMI-COMPLIED SHEET G-101 THE BUILDING DATA |
| INDICATES A BUILDING TYPE III-B AND BUSINESS OCCUPANCY |
| PLEASE SEE COMMENTS LISTED UNDER COMMENET # 2 & 3. |
| |
| |
| 2 ) THE PLANS THAT WERE SUBMITTED ARE CONCEPTUAL IN |
| NATURE A THOROUGH REVIEW CAN NOT BE COMPLETED AT THIS |
| TIME. FBC-B 106.3.5THE MINIMUM PLAN REVIEW CRITERIA FOR |
| COMMERCIAL BUILDINGS ARE AS FOLLOWS: |
| BUILDING |
| |
| 1. SITE REQUIREMENTS: |
| |
| SET BACK/SEPARATION (ASSUMED PROPERTY LINES OR DISTANCE |
| FROM THE PROPERTY LINE TO EACH OF THE STRUCTURES) |
| |
| 2. SECOND REQUEST OCCUPANCY GROUP AND SPECIAL OCCUPANCY |
| REQUIREMENTS SHALL BE DETERMINED. |
| SHEET G-101 CLEARLY STATES THESE BUILDINGS ARE TO BE |
| BUSINESS OCCUPANCY. THE EXISTING BUILDING INDICATES A |
| MULTI-PURPOSE ROOM AND THE PLANS STATE THE BUILDINGS |
| ARE ATHLETIC LEAGUE ACTIVITY CENTERS. THE EXISTING & |
| NEW ADDITION ARE TO BE CONSIDERED A-3 OCCUPANCY, A |
| COMMUNITY CENTER . PLEASE REVIEW FBC-B 303.1 |
| |
| 3.SECOND REQUEST, MINIMUM TYPE OF CONSTRUCTION SHALL BE |
| DETERMINED (SEE TABLE 503). HEIGHT AND AREA ARE TAKEN |
| FOR A BUSINESS OCCUPANCY, PLEASE REVIEW FBC-B 303.1 AND |
| TABLE 503 FOR ALLOWABLE HEIGHT AND AREA. |
| |
| 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL |
| INCLUDE THE FOLLOWING COMPONENTS: |
| FIRE -RESISTANCE BASED ON SEPERATION |
| FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION |
| PLANS INDICATE A REQUIRED 2 HR EXTERIOR BEARING WALL, |
| PLEASE PROVIDE THE EQUIVALENT THICKNESS FOR THE 2 HR |
| RATED BLOCK FROM THE MANUFACTURER.FBC-B 721.2.1.1 & |
| TABLE 721.2.1.1. |
| |
| 5. N/A |
| |
| |
| 6.SECOND REQUEST, LIFE SAFETY SYSTEMS SHALL BE |
| DETERMINED : |
| OCCUPANT LOAD AND EGRESS CAPACITIES |
| CURRENTLY IT APPEARS THE WRONG OCCUPANCY TYPE HAS BEEN |
| LISTED FOR THE NEW CONSTRUCTION AND FOR THE EXISTING |
| TWO STORY . |
| |
| |
| 7. COMPLIED. |
| 8A) . STRUCTURAL REQUIREMENTS SHALL INCLUDE: |
| SOIL CONDITIONS/ANALYSIS:1802.2.1 QUESTIONABLE SOIL. |
| WHERE THE SAFE-SUSTAINING POWER OF THE SOIL IS IN |
| DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT |
| SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING |
| OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION |
| BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE |
| PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . |
| |
| 8B) BUILDING ENVELOPE (PRODUCT APPROVALS) |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, PROVIDE 2 |
| COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE |
| AS FOLLOWS: |
| WINDOWS |
| ROOFING ASSEMBLIES |
| |
| 9-12). COMPLIED. |
| |
| |
| |
| 13.)P COMPLIED. PLAY GROUND EQUIPMENT FUTURE- UNDER |
| SEPERATE PERMIT |
| |
| 14)COMPLIED. |
| |
| INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| NOTICE. |
| |
| OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| - 5:00 PM. |
| |
| JIM WITMER C. B. O. |
| COMMERCIAL COMBINATION PLAN REVIEW |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |
| PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| CUSTOMER SERVICE SURVEY AT: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |