2010-04-12 09:35:55****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE FOR
 EXPOSURE B. FBC1609, FBC R301.2.1.4. NOTE THAT THE CODE
 CHANGED EFFECTIVE MARCH 1, 2009. AN OPEN AREA IS
 LOCATED WITHIN 1500 FEET TO THE WEST OF THIS PROPERTY.
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
 BOTH THE WINDOWS AND THE SHUTTERS REQUIRE HIGHER
 PRESSURES FOR EXPOSURE C. PLEASE REVISE MARKED PRODUCT
 APPROVALS AND SHUTTER INSTALLATION SCHEDULE
 ACCORDINGLY.
  
 PLEASE NOTE THAT IN THE FUTURE PERMITS MAY BE ISSUED
 WITH PROVISO FOR A REVISION PROVIDING THE REQUIRED
 INFORMATION TO SHOW CODE COMPLIANCE (RATHER THAN
 DENIED).
  
  
  