2010-04-05 18:20:50PLANNING AND ZONING: **** FAILED ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
 SHOW ALL DIMENSIONS AND SETBACKS FROM ALL PROPERTY
 LINES.
  
 3. PURSUANT TO SECTION SEC. 94-74(3) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS ("ZLDR"), THE MINIMUM
 SETBACKS FOR PRINCIPAL BUILDING IN A SINGLE-FAMILY HIGH
 DENSITY ("SF14") RESIDENTIAL DISTRICT IS AS FOLLOWS:
  
 A. FRONT: 25 FEET;
 B. CORNER: 12.5 FEET;
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL
  
 4. IS THE SCOPE OF WORK ENCLOSING AN AREA WHERE
 EXISTING COLUMNS ARE? THE PERMIT AND PLANS ARE NOT
 CLEAR.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  