Plan Review Notes
Plan Review Notes For Permit 10020368
Permit Number 10020368
Review Stop B
Sequence Number 1
Notes
Date Text
2010-02-25 08:20:28BUILDING PLAN REVIEW
 PERMIT: 10020368
 ADD: 1801 CENTREPARK 1ST FLOOR RESTROOMS
 CONT: ANDERSON MOORE
 TEL: (561)662-1819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 FEB. 25/2010
  
 1) SHEET A-1 DETAILS 1& 2 THE LADIES WATER CLOSETS WITH
 6 WATER CLOSETSPLEASE REVIEW SECTION 11-4.22.4 THAT
 REQUIRES A AMBLATORY STALL.
  
 2) SHEET A-1 DETAILS 1& 2 THE LADIES AMBLATORY STALL
 DOOR MUST HAVE A OUT SWING DOOR WITH 32 INCHES CLEAR
 SEE FIGURE 30(B).
  
 3) SHEET A-2 THE WOMENS ELEVATIONS AT THE STALLS
 INDICATES WALL COVERING, NO NOTE ABOUT COMPLIANCE
 WITH:1210.2 WALLS. WALLS WITHIN 2 FEET (610 MM) OF
 URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM)
 ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS,
 THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE
 THAT IS NOT ADVERSELY AFFECTED BY MOISTURE.
  
 4) SHEET A-2 DETAILS FOR AN ACCESSIBLE LAV ARE PROVIDED
 (2'-5") , BUT IN THE ELEVATION VIEW THE SKIRT IN FRONT
 OF THE LAV IS NOT PROVIDED NOR THE MEASUREMENT FROM THE
 BOTTOM OF THE SKIRT TO THE FLOOR SURFACE. PLEASE REVIEW
 FIGURE 31 WITH A CLEAR HEIGHT. NOTE THE PLANS INDICATE
 THE FINISH COUNTER HEIGHT IS PROVIDED AT 2'-9", THE
 CLEAR HEIGHT FOR THE KNEES MUST STILL BE MAINTAINED!!!
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved