2010-02-18 11:41:52BUILDING PLAN REVIEW
 PERMIT: 09100528/ REV 10020057
 ADD:101 NORTHPOINT PKWY # 105
 CONT: ANDERSON MOORE CONSTRUCTION
 TEL: (561)662-1819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW REVISION
 SHEET LA-1
  
 BUILDING PROVISO:
  
 11-4.1.2 ACCESSIBLE SITE AND EXTERIOR FACILITIES:
 (7) BUILDING SIGNAGE. SIGNS WHICH DESIGNATE PERMANENT
 ROOMS AND SPACES SHALL COMPLY WITH SECTIONS 11-4.30.1,
 11-4.30.4, 11-4.30.5 AND 11-4.30.6. OTHER SIGNS WHICH
 PROVIDE DIRECTION TO, OR INFORMATION ABOUT, FUNCTIONAL
 SPACES OF THE BUILDING SHALL COMPLY WITH SECTIONS
 11-4.30.1, 11-4.30.2, 11-4.30.3, AND 11-4.30.5.
 ELEMENTS AND SPACES OF ACCESSIBLE FACILITIES WHICH
 SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF
 ACCESSIBILITY AND WHICH SHALL COMPLY WITH SECTION
 11-4.30.7 ARE:
  
 (C) ACCESSIBLE ENTRANCES WHEN NOT ALL ARE ACCESSIBLE
 (INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNAGE
 TO INDICATE THE ROUTE TO THE NEAREST ACCESSIBLE
 ENTRANCE);
  
 11-4.30 SIGNAGE:
 11-4.30.3 CHARACTER HEIGHT. CHARACTERS AND NUMBERS ON
 SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING DISTANCE
 FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS
 MEASURED USING AN UPPER CASE "X." LOWER CASE CHARACTERS
 ARE PERMITTED.
  
 MINIMUM CHARACTER HEIGHT 3 INCHES (75 MM) MINIMUM
  
 11-4.30.4 RAISED AND BRAILLED CHARACTERS AND PICTORIAL
 SYMBOL SIGNS (PICTOGRAMS). LETTERS AND NUMERALS SHALL
 BE RAISED 1/32 INCHES (.8 MM), UPPER CASE, SANS SERIF
 OR SIMPLE SERIF TYPE AND SHALL BE ACCOMPANIED WITH
 GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST
 5/8 INCHES (16 MM) HIGH, BUT NO HIGHER THAN 2 INCHES
 (51 MM). PICTOGRAMS SHALL BE ACCOMPANIED BY THE
 EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE
 PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL
 BE 6 INCHES (152 MM) MINIMUM IN HEIGHT.
  
 11-4.30.5 FINISH AND CONTRAST. THE CHARACTERS AND
 BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OR OTHER
 NONGLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST
 WITH THEIR BACKGROUND???EITHER LIGHT CHARACTERS ON A
 DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT
 BACKGROUND.
  
 11-4.30.6 MOUNTING LOCATION AND HEIGHT. WHERE PERMANENT
 IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, SIGNS
 SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH
 SIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE
 LATCH SIDE OF THE DOOR, INCLUDING AT DOUBLE LEAF DOORS,
 SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL.
 MOUNTING HEIGHT SHALL BE 60 INCHES (1525 MM) ABOVE THE
 FINISH FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING
 LOCATION FOR SUCH SIGNAGE SHALL BE SO THAT A PERSON MAY
 APPROACH WITHIN 3 INCHES (76 MM) OF SIGNAGE WITHOUT
 ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE
 SWING OF A DOOR.
  
 11-4.30.7 SYMBOLS OF ACCESSIBILITY.
 (1) FACILITIES AND ELEMENTS REQUIRED TO BE IDENTIFIED
 AS ACCESSIBLE BY SECTION 11-4.1 SHALL USE THE
 INTERNATIONAL SYMBOL OF ACCESSIBILITY. THE SYMBOL SHALL
 BE DISPLAYED AS SHOWN IN FIGURE 43(A) AND FIGURE 43(B).
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]