Plan Review Notes
Plan Review Notes For Permit 10010214
Permit Number 10010214
Review Stop L
Sequence Number 2
Notes
Date Text
2010-07-28 13:25:56***LANDSCAPE REVIEW FAILED***
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. REPEAT COMMENT: A SEPARATE IRRIGATION PERMIT IS
 REQUIRED. STRIPING REVISIONS SHOULD BE TIED WITH THE
 PAVING PERMIT. A CERTIFIED COST ESTIMATE THAT INCLUDES
 THE TOTAL COST OF ALL LANDSCAPE MATERIALS AND LABOR
 SHALL BE SUBMITTED WITH THE LANDSCAPE PACKAGE.
  
 2. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (C) (3)
 (A), EACH ROW OF PARKING SPACES SHALL BE TERMINATED BY
 LANDSCAPE ISLANDS OF NOT LESS THAN FIVE FEET IN WIDTH,
 EXCLUDING THE REQUIRED CURB, AND NOT LESS THAN THE
 LENGTH OF THE ADJACENT PARKING STALL. THE LANDSCAPED
 ISLAND SHALL HAVE A MINIMUM RADIUS OF 2 1/2 FEET AT ITS
 END SO AS TO ALLOW CAR MANEUVERING. THE LANDSCAPED
 ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR FLOWERING
 TREE. THIS APPLIES TO THE PAVED AREA ON THE EAST SIDE
 OF THE WALL IN THE LOCATION OF THE EXISTING DUMPSTER.
 THE ENTIRE TRIANGULAR AREA SHALL BE CUT OUT AND
 LANDSCAPED. ALSO A TREE IS REQUIRED IN THE TERMINAL
 ISLAND AT THE SOUTH END OF THE PARKING ROW ADJACENT TO
 THE TENNIS COURTS.
  
 3. REPEAT COMMENT: THE HEIGHT OF THE PLANT MATERIAL
 REQUIRED TO SCREEN THE LIFT STATION SHALL BE TALL
 ENOUGH TO OBSCURE THE VIEW OF THE ITEMS BEING SCREENED.
 THE VINES THAT WERE ALREADY PLANTED ARE TOO SMALL AND
 DO NOT SCREEN THE CHAIN FENCE SURROUNDING THE LIFT
 STATION.
  
 4. REPEAT COMMENT: THE USE OF GEIGER TREES ALONG THE
 SIDES OF THE PARKING LOT DOES NOT RELATE TO WHAT IS
 CURRENTLY PLANTED. PLEASE MATCH THE TREE SPECIES IN
 THESE LOCATIONS TO THOSE THAT ARE ALREADY PLANTED.
  
 5. REPEAT COMMENT: THE DUMPSTER ENCLOSURE DETAIL SHOWS
 VISION OBSCURING GATES. THE ENCLOSURE AND VISION
 OBSCURING GATES ARE NOW SHOWN ON THE SITE PLAN BUT NOT
 ON THE LANDSCAPE PLAN. ALL PLANS SHALL BE CONSISTENT.
  
 6. REPEAT COMMENT: THOUGH THE LANDSCAPE CODE ALLOWS
 PROPOSED TREES TO BE A MINIMUM OF EIGHT FEET IN HEIGHT
 WITH FIVE FEET OF CLEAR TRUNK, ALL TREES MUST BE
 FLORIDA NUMBER 1 GRADE OR BETTER. NO TREE THAT IS EIGHT
 FEET IN HEIGHT WITH FIVE FEET OF CLEAR TRUNK CAN MEET
 THIS GRADE STANDARD. PLEASE INCREASE THE HEIGHT OF
 THESE TREES.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.