Plan Review Notes For Permit 09120196 |
Permit Number |
09120196 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2009-12-23 14:17:30 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. DETAILS PROVIDED FROM THE AAF GUIDE ARE FOR ALUMINUM | | POSTS, PLAN SHOWS WOOD POSTS. PROVIDE APPROPRIATE | | DETAILS/CONNECTION SPECIFICATIONS. | | | | THE DETAILS SENT VIA EMAIL CONFLICT WITH THE AAF | | STANDARD WALL DETAIL, PAGE 3-3. A CURSORY REVIEW WAS | | DONE; PLEASE NOTE THAT WE DO NOT ACCEPT RESUBS VIA | | EMAIL AT THIS TIME. FOR EXAMPLE, AN EMAIL WAS SENT WITH | | DETAIL C3 CIRCLED, BUT THE WALL DETAIL (AAF PAGE 3-3) | | SHOWS DETAIL C7/C8 AT THIS LOCATION (INTERMEDIATE | | POSTS). PLEASE REVISE THE PLAN TO SHOW LOCATION OF | | PROPOSED DETAILS AND CONFIRM THAT PLANS SUBMITTED ARE | | CONSISTENT WITH THIS SPECIFIC JOB. | | | | NEW COMMENT: | | | | 2. THE EXISTING PORCH WAS DESIGNED TO BE OPEN; PLEASE | | INCLUDE INFORMATION REGARDING THE HOST STRUCTURE'S | | ABILITY TO RESIST ADDITIONAL WIND LOADS CREATED BY THE | | SCREEN ENCLOSURE. FBC R301.1. | | | | PLEASE REVISE PLANS AND RESUBMIT, TWO SETS. | | |
|