Plan Review Notes
Plan Review Notes For Permit 09110398
Permit Number 09110398
Review Stop B
Sequence Number 2
Notes
Date Text
2010-02-24 08:49:01BUILDING PLAN REVIEW
 PERMIT: 09110398
 ADD: 2301 CENTRE PARK WEST DR SUITE# 100
 CONT: ANDERSON & MOORECONSTTRUCTION CORP
 TEL: (561) 662-1819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 PLANS DO NOT INDICATE IF THIS IS A FIRE SPRINKLERED
 BUILDING. SHEET A3 INDICATES DOOR TYPE "B" TO BE A 20
 MINUTE RATED DOOR. TENANT SEPERATION WALLS ARE REQUIRED
 TO BE 1 HOUR PER FBC BUILDING 708.1. TABLE 715.4
 REQUIRES 45MINUTE RATED DOORS FOR NON-SPRINKLERED
 BUILDING AND 20 MINUTE FOR FIRE SPRINKLERED BUILDINGS.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved