2009-11-12 14:48:56RESIDENTIAL (R2) REROOF, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- THIS IS A SINGLE FLAT ROOF. PARTIAL RE-ROOF IS NOT
 ALLOWED. NEED TO RE-ROOF ENTIRE ROOF. SEC. 611.1.1 OF
 2007 FBC.
  
 2- NOA 03-0501.02 SUBMITTED EXPIRED LAST YEAR ON
 11/06/08. NEED TO PROVIDE CURRENT NOA.
  
 3- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED TO MEET THE
 DESIGN PRESSURES OF SEC. 1609 FBC 2007.
 ***NOTES: A) IF GENERAL LIMITATION #7 ON NOA PROVIDE
 REQUIRES RAS 117 CALCULATIONS TO BE SIGNED AND SEALED,
 THEN SIGNED AND SEALED CALCULATIONS ARE REQUIRED.
  
 B) DESIGN PROFESSIONAL DOING THE RAS 117 CALCULATIONS
 TO TAKE INTO CONSIDERATION THAT ACCORDING TO THE 2009
 REVISIONS TO THE 2007 FBC THIS BUILDING IS LOCATED ON
 EXPOSURE "C", NOT "B".
  
 4) ROOF TOP EQUIPMENT REQUIRES SEPARATE PERMIT.
  