Plan Review Notes For Permit 09100489 |
Permit Number |
09100489 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2009-11-17 12:05:40 | 2007 FBC W/2009 REVISIONS | | STORM PANELS | | | | DENIED | | | | 1) DIRECT MOUNT IS SPECIFIED FOR SOME OF THE STORM | | PANEL CONNECTION TYPES AND THE ONLY ANCHORS THAT ARE | | SPECIFIED ARE TAPCONS. TAPCONS ARE NOT ACCEPTABLE FOR | | DIRECT MOUNT PER PRODUCT APPROVAL. | | | | 2) TABLE 2 NOTE ON PAGE 6 OF THE PRODUCT APPROVAL | | SPECIFIES A MINIMUM PANEL LENGTH FOR THE VARIOUS | | MOUNTING CONDITIONS. THE TABLE STATES THAT PANEL | | LENGTHS LESS THAN THOSE NOTED IN THE TABLE REQUIRE SITE | | SPECIFIC POROSITY CALCULATIONS BY A PROFESSIONAL | | ENGINEER. SOME OF THE PANEL LENGTHS ARE LESS THAN THE | | MINIMUMS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|