2009-10-27 11:39:57 | RESIDENTIAL (R3) REROOF, BUILDING REVIEW CHECKLIST. | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- FLAT ROOF PRODUCT APPROVAL SUBMITTED: | | A) ACCORDING TO THE MIAMI-DADE PRODUCT APPROVAL WEBSITE | | NOA 06-0410.06 FILE IS CLOSED. NEED TO PROVIDE CURRENT | | NOA. | | | | B) ACCORDING TO GENERAL LIMITATION #7 ON LAST PAGE OF | | NOA SUBMITTED, NEED TO PROVIDE RAS 117 CALCULATIONS FOR | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS TO COMPLY | | WITH THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA | | RESIDENTIAL CODE. | | | | C) ACCORDING TO GENERAL LIMITATION #7 ON LAST PAGE OF | | NOA SUBMITTED THE RAS 117 CALCULATIONS NEED TO BE | | SIGNED AND SEALED. PROVIDE SIGNED AND SEALED RAS 117 | | CALCULATIONS. | | | | D) CLARIFY WHICH APPROVED ASSEMBLY IS GOING TO BE | | INSTALLED. THERE ARE TWO DIFFERENT ASSEMBLIES | | SUBMITTED. ON E ON PAGE 42 AND THE OTHER ONE ON PAGE | | 43. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|