2009-10-22 11:56:59 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | CODE | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FS FLORIDA STATUTE | | | | 1. DECLARE WIND DESIGN CRITERIA, FBC1603.1.4. | | | | 2. PLEASE SEE FBC CHAPTER 35, CORRECT ASCE7 REFERENCE | | IS 05 RATHER THAN 02. | | | | 3. PROVIDE A SITE PLAN SHOWING PROPOSED AWNING | | LOCATION, FBC CHAPTER 10, FBC3307. IS THIS OVER THE | | PUBLIC WAY, REQUIRING ENGINEERING APPROVAL? | | | | 4. PROVIDE INFORMATION REGARDING THE PROPOSED AWNING | | ELEVATION. AN ELEVATION NOTE OF 112'6" WAS INCLUDED, | | BUT DOES NOT GIVE ANY OTHER INFORMATION (SUCH AS | | ELEVATION OF GRADE). IT APPEARS THAT THIS IS ONLY A | | REFERENCE ELEVATION. | | | | AS DISCUSSED, THE ABOVE ITEMS CAN BE ISSUED AS A | | PROVISO IF APPROVED BY THE ENGINEER. PLEASE FEEL FREE | | TO CONTACT ME IF YOU NEED FURTHER ASSISTANCE. | | | | | | |
|