Plan Review Notes For Permit 09090649 |
Permit Number |
09090649 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2009-10-19 16:14:42 | NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW | | CHECKLIST. | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- SHEET A2: SPECIFY ALL LIVE AND DEAD LOADS INCLUDING | | THE ATTIC LIVE LOAD AS REQUIRED BY SEC. R301.1 AND | | TABLE R301.5 OF 2007 FLORIDA RESIDENTIAL CODE. | | ***NOTE: STRUCTURAL NOTE REGARDING THE ROOF LOADS IS | | INCOMPLETE AND DOESN'T SPECIFY ALL DESIGN LOADS. | | EXPLAIN WHAT IS "ALL DEAD LOADS PLUS 20PSF LIVE LOAD" | | ?. | | | | 2- CLARIFY HOW IS THE ROOF VENTILATION REQUIRED BY SEC. | | R806 OF 2007 FLORIDA RESIDENTIAL CODE TAKEN CARE OF. | | | | 3- SPECIFY ATTIC SIZE AND LOCATION AS REQUIRED BY SEC. | | R807. PLANS ONLY SHOW A NOTE BY THE HALLWAY STATING " | | ATTIC ACCESS". BUT, THERE IS NO SIZE AND SPECIFIC | | LOCATION SPECIFIED. | | | | 4- A) PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED | | BY DCA RULE 9B-72 FOR THE HARDI BOARD TO BE INSTALLED. | | | | B) ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | PRODUCT APPROVAL PRIOR TO SUBMITTAL. | | | | 5- BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT | | FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY OF PAID | | RECEIPT IF FEES ARE DUE. | | | | 6- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDA STATUTE. | | **NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | 7- OWES $15.92 FOR RADON FEES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|