Plan Review Notes
Plan Review Notes For Permit 09090630
Permit Number 09090630
Review Stop B
Sequence Number 1
Notes
Date Text
2009-10-01 08:05:46****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. SHEET T, EXISTING OCCUPANCY IS NOTED AS B, WASN'T
 THIS DESIGNED AS A LIVE/WORK SPACE, MIXED, B/R2? PLEASE
 REVISE AND NOTE THAT THIS IS A CHANGE OF OCCUPANCY, FBC
 CH 3, FBC EXISTING BUILDING CODE.
  
 2. FBC11-4.1.3(5), VERTICAL ACCESSIBILITY REQUIRED. IF
 AN EXCEPTION APPLIES, PLEASE SHOW COMPLIANCE WITH ALL
 RQUIREMENTS ON THE PLAN. (NOTE THAT THE AREA IS NOT
 OPEN TO THE PUBLIC, DECLARE OCCUPANT LOAD OF 5 OR
 LESS.)
  
 3. FBC11-4.1.3(5), DECLARE SQUARE FOOT AREA FOR
 MEZZANINES. TOTAL SQUARE FOOT AREA WAS PROVIDED BUT SF
 FOR MEZZANINE AREA IS REQUIRED TO SHOW COMPLIANCE WITH
 OTHER ITEMS.
  
 4. IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY,
 233-5025. PLEASE PROVIDE STAMPED PLAN AND RECEIPT.
  
 5. THE MEZZANINE WAS REVIEWED AS RESIDENTIAL WHEN THE
 BUILDING WAS CONSTRUCTED. IT IS NOT CLEAR WHETHER THE
 CURRENT STAIRS, THEN ELIGIBLE TO BE BUILT UNDER
 RESIDENTIAL REQUIREMENTS, MEET REQUIREMENTS FOR
 BUSINESS OCCUPANCY, FBC1009, 1009.8. PROVIDE A DETAIL
 FOR THE STAIRS AND THE SPIRAL STAIRS.
  
 6. FBC505.4, OPENNESS FOR MEZZANINES, AND FBC505.2,
 AREA LIMITATION, EITHER REVISE PLAN TO COMPLY OR SHOW
 EXCEPTION ON THE PLAN.
  
 AS DISCUSSED, ISSUANCE WITH PROVISO IS POSSIBLE IF ALL
 OTHER TRADES PASS REVIEW.
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved