2009-10-01 17:01:02 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| CHECKLIST. |
| 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| |
| 1- BRING PLANS TO PALM BEACH COUNTY TO VERIFY IF IMPACT |
| FEES ARE DUE. PLEASE, BRING BACK STAMPED PLANS AND COPY |
| OF PAID RECEIPT IF FEES ARE DUE. |
| |
| 2- PROVIDE ENERGY CALCULATIONS. PLEASE, MAKE SURE |
| CORRECT UPDATED AND COMPLETE FORM IS PROVIDED AND ALL |
| SIGNATURES AND DATES ARE INCLUDED. |
| |
| 3- PROVIDE COMPLETE FRAMING DETAILS FOR ALL NEW DOORS |
| AND WINDOWS INSTALLATION, INCLUDING GARAGE DOOR TO |
| VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SECTION |
| R301 OF 2007 FLORIDA RESIDENTIAL CODE. SPECIFY ALL |
| FRAMING MEMBERS AND ANCHORS. |
| |
| 4- PROVIDE DETAILS/SPECIFICATIONS SHOWING HOW IS THE |
| EXISTING ROOF GOING TO BE REINFORCED IF THE TRUSSES |
| BOTTOM CHORD IS GOING TO BE REMOVED IN THE CABANA AREA. |
| TRUSSES BEARING POINTS ARE CHANGED WHEN REMOVING THE |
| TRUSS WEBS AND BOTTOM CHORD. SEC. 106.1.2 OF CITY |
| AMENDMENTS TO FBC TO VERIFY COMPLIANCE WITH THE DESIGN |
| LOADS OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL CODE. |
| |
| 5- SECTION "C" ON SHEET A1: SPECIFY ROOF VENTILATION |
| SIZE AND LOCATION TO VERIFY COMPLIANCE WITH SEC. R806. |
| |
| 6- PROVIDE NOTICE OF COMMENCEMENT. SEC. 713.13 FLORIDA |
| STATUTE. |
| ***NOTE: THIS MAY BE PROVIDED AT TIME OF PERMIT PICK |
| UP. |
| |
| 7- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND |
| APPROVED IN WRITING (NOT SIGNING AND SEALING) BY THE |
| ENGINEER OF RECORD AS REQUIRED BY SEC. 106.3.3 CITY |
| AMENDMENTS TO FBC. |
| |
| JULIO GOMEZ |
| COMBINED COMMERCIAL PLANS EXAMINER |
| (561)805-6712 |