2009-09-17 19:02:40 | ****CORRECTIONS**** |
| ****REVISED 10/1/9**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2007 |
| FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| |
| 1. SHEET T, EXISTING OCCUPANCY IS NOTED AS B, WASN'T |
| THIS DESIGNED AS A LIVE/WORK SPACE, MIXED, B/R2? PLEASE |
| REVISE AND NOTE THAT THIS IS A CHANGE OF OCCUPANCY, FBC |
| CH 3, FBC EXISTING BUILDING CODE. |
| |
| 2. FBC11-4.1.3(5), VERTICAL ACCESSIBILITY REQUIRED. IF |
| AN EXCEPTION APPLIES, PLEASE SHOW COMPLIANCE WITH ALL |
| RQUIREMENTS ON THE PLAN. |
| |
| 3. FBC11-4.1.3(5), DECLARE SQUARE FOOT AREA FOR |
| MEZZANINES. |
| |
| 4. IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY, |
| 233-5025. PLEASE PROVIDE STAMPED PLAN AND RECEIPT. |
| |
| 5. TOILET ROOM 204 TO BE ADAPTABLE. PLEASE SHOW BACKING |
| DETAIL FOR FUTURE GRAB BARS, FBC11.4.1.3(11). (TURNING |
| RADIUS NOT REQUIRED PER DW) |
| |
| 6. THE MEZZANINE WAS REVIEWED AS RESIDENTIAL WHEN THE |
| BUILDING WAS CONSTRUCTED. IT IS NOT CLEAR WHETHER THE |
| CURRENT STAIRS, THEN ELIGIBLE TO BE BUILT UNDER |
| RESIDENTIAL REQUIREMENTS, MEET REQUIREMENTS FOR |
| BUSINESS OCCUPANCY, FBC1009, 1009.8. PROVIDE A DETAIL |
| FOR THE STAIRS AND THE SPIRAL STAIRS. |
| |
| 7. SHOW MANEUVERING CLEARANCE, PULL SIDE, PER FBC |
| FIGURE 11-25 FOR DOORS AT TOILET 105, CORRIDOR 119 (BY |
| CL122). |
| |
| 8. FBC1008.1.2, DOOR C MUST BE SIDESWINGING OR MUST |
| COMPLY WITH FBC1008.1.3.3. |
| |
| 9. FBC505.4, OPENNESS FOR MEZZANINES, AND FBC505.2, |
| AREA LIMITATION, EITHER REVISE PLAN TO COMPLY OR SHOW |
| EXCEPTION ON THE PLAN. |
| |
| 10. MR BOARD SHOWN ON WALL DETAILS ON A4; SEE |
| FBC2509.3, LIMITATIONS, NOT CLEAR WHERE MR BOARD IS |
| PROPOSED. |
| |
| 11. ENERGY CALCS, INCLUDE THE NAME OF ARCHITECT AND |
| LICENSE NUMBER AS THE PERSON WHO IS CERTIFYING THAT |
| PORTION OF THE ENERGY CALC, FBC13-103.1.1.1. |
| |
| |
| |