2010-05-03 16:35:04 | BUILDING PLAN REVIEW |
| PERMIT: 09090218 |
| ADD: 5011 BROADWAY AV |
| CONT: TO BE DETERMINED |
| TEL: (786)368-6455 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE W/ 2009 |
| SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2ND REVIEW |
| ACTION: DENIED |
| DATE MAY 03 /2010 |
| SHEET A-1 SITE PLAN NOTES & CODE INFORMATION: |
| |
| 1) A-E COMPLIED. |
| F) IF THIS PERMIT IS TO BE PHASED PLEASE PROVIDE TIME |
| LINES FOR EACH PHASE, THE BUILDING OFFICIAL MAY REQUIRE |
| SEPARATE PERMITS DEPENDING ON THE PHASED TIME LINE. |
| |
| 2) NOTE PRODUCT APPROVALS ARE NOT REQUIRED AT TIME OF |
| PERMIT ISSUANCE BUT WILL BE CONSIDERED A REVISION AND A |
| SEPARATE REVIEW AND ASSOCIATED FEES |
| WOULD BE REQUIRED. |
| FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, PROVIDE 2 |
| COPIES OF PRODUCT TESTING REPORTS ,MISSING REPORTS ARE |
| AS FOLLOWS: |
| A) FIXED GLASS/ STORE FRONT |
| B) EXTERIOR GLAZED SWING DOORS & SIDELIGHTS |
| C) SINGLE EXTERIOR HOLLOW METAL SWING DOORS |
| D) PAIRS OF EXTERIOR HOLLOW METAL SWING DOORS |
| E AUTOMATIC SLIDING DOORS& SIDE LIGHTS |
| F) TRUSS ANCHORS |
| G) WALL LOUVERS- DECORATIVE SHUTTERS |
| H) EFIS WALL SYSTEMS |
| I) SHUTTERS BAHAMAN STYLE- ON TOWERS |
| J) ROOF ASSEMBLY???S UNDERLAYMENT, MODIFIED BITUMEN & |
| ROOF TILE |
| |
| 3A) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT |
| IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR |
| LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE |
| 9B-72. |
| |
| 3B) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| |
| |
| 4) 2ND REQUEST, FLOOR PLAN A-3 INDICATES USE OF POWER |
| HORIZONTAL SLIDING DOORS. SHOW COMPLIANCE WITH: |
| 1008.1.3.3 HORIZONTAL SLIDING DOORS. IN OTHER THAN |
| GROUP H OCCUPANCIES, HORIZONTAL SLIDING DOORS PERMITTED |
| TO BE A COMPONENT OF A MEANS OF EGRESS IN |
| ACCORDANCE WITH EXCEPTION 5 TO SECTION 1008.1.2 SHALL |
| COMPLY WITH ALL OF THE FOLLOWING CRITERIA: |
| 1. THE DOORS SHALL BE POWER OPERATED AND SHALL BE |
| CAPABLE OF BEING OPERATED MANUALLY IN THE EVENT OF |
| POWER FAILURE. |
| 2. THE DOORS SHALL BE OPEN ABLE BY A SIMPLE METHOD FROM |
| BOTH SIDES WITHOUT SPECIAL KNOWLEDGE OR EFFORT. |
| 3. THE FORCE REQUIRED TO OPERATE THE DOOR SHALL NOT |
| EXCEED 30 POUNDS (133 N) TO SET THE DOOR IN MOTION AND |
| 15 POUNDS (67 N) TO CLOSE THE DOOR OR OPEN IT TO THE |
| MINIMUM REQUIRED WIDTH. |
| 4. THE DOOR SHALL BE OPERABLE WITH A FORCE NOT TO |
| EXCEED 15 POUNDS (67 N) WHEN A FORCE OF 250 POUNDS |
| (1100 N) IS APPLIED PERPENDICULAR TO THE DOOR ADJACENT |
| TO THE OPERATING DEVICE. |
| 5. THE DOOR ASSEMBLY SHALL COMPLY WITH THE APPLICABLE |
| FIRE PROTECTION RATING AND, WHERE RATED, SHALL BE |
| SELF-CLOSING OR AUTOMATIC-CLOSING BY |
| SMOKE DETECTION, SHALL BE INSTALLED IN ACCORDANCE WITH |
| NFPA 80 AND SHALL COMPLY WITH SECTION 715 . |
| 6. THE DOOR ASSEMBLY SHALL HAVE AN INTEGRATED STANDBY |
| POWER SUPPLY. |
| 7. THE DOOR ASSEMBLY POWER SUPPLY SHALL BE ELECTRICALLY |
| SUPERVISED. |
| |
| RESPONSE FROM THE DESIGN PROFESSIONAL WAS TO SITE THE |
| CODE SECTION NOT TO PRODUCE MANUFACTURER???S SPEC OF |
| DOOR INDICATING COMPLIANCE. 106.1.1* W.P.B. |
| ADMINISTRATIVE CODE/2004 DRAWINGS & SPECIFICATIONS |
| SHALL CONTAIN INFORMATION, IN THE FORM OF NOTES OR |
| OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE |
| QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL |
| CODES. SUCH INFORMATION SHALL BE SPECIFIC TO THE |
| TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR IN |
| PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED AS |
| A SUBSTITUTE FOR SPECIFIC INFORMATION". |
| |
| 5A) 2ND REQUEST, THE FOLLOWING ITEMS WILL DEAL WITH |
| ROOFING REPORTS BE ADVISED OF THE INFORMATION THAT WILL |
| NEED TO BE HIGHLIGHTED BEFORE SUBMITTAL TO THE BUILDING |
| DEPARTMENT; THIS ROOF IS MISSING OR NOT IN COMPLIANCE |
| WITH THE FOLLOW ITEMS: |
| (FLAT ROOF) |
| ___ CONTRACTOR DID NOT PROVIDE THE MEAN ROOF HEIGHT. |
| ___ CONTRACTOR DID NOT INDICATE THE ROOF PITCH. ___ |
| CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO BE USED. |
| ___ THE SYSTEM PROVIDED HAS A LOW PRESSURE FOR ZONE ___ |
| . |
| ___ THE SYSTEM PROVIDED STATES LIMITATION# 7, SHOULD |
| THE FASTENER RESISTANCE BE LESS THAN THAT REQUIRED, AS |
| DETERMINED BY THE |
| BUILDING OFFICIAL, A REVISED FASTENER SPACING, PREPARED |
| , SIGNED AND SEALED BY A FLORIDA REGISTERED |
| PROFESSIONAL ENGINEER, REGISTERED |
| ARCHITECT OR REGISTERED ROOF CONSULTANT MAY BE |
| SUBMITTED. |
| ___ THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO |
| ENHANCED FASTENING ALLOWED. |
| |
| 5B) 2ND REQUEST, ROOF TILE FOR SLOPED ROOFS, PLEASE |
| INDICATE WHICH FASTENING SYSTEM SHALL BE USED.106.1.2 |
| ADDITIONAL INFORMATION REQUIRED. MOMENT OF OVERTURNING, |
| 1609.7.3 RIGID TILE. |
| |
| 5C) 2ND REQUEST, NO INFORMATION FOR FASTENING OF HIP |
| BOARD OR HIP TILE. 1507.3.8 APPLICATION. TILE SHALL BE |
| APPLIED ACCORDING TO THE MANUFACTURER'S INSTALLATION |
| INSTRUCTIONS OR RECOMMENDATIONS OF THE FRSA/RTI |
| 07320/08-05 (FOURTH EDITION). |
| |
| 6A) COMPLIED. |
| |
| 6B)2ND REQUEST, STRAPPING OVER THE UNIT DOES NOT |
| CONSTITUTE MEETING THIS CODE SECTION. 301.13 FBC |
| MECHANICAL. WIND RESISTANCE. MECHANICAL EQUIPMENT, |
| APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL |
| BE DESIGNED AND INSTALLED TO RESIST WIND PRESSURES ON |
| THE EQUIPMENT AND THE SUPPORTS AS DETERMINED IN |
| ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING. |
| THIS CODE SECTION IS NOT ONLY FOR THE ATTACHMENT OF THE |
| UNIT TO THE STRUCTURAL MEMBERS BUT THE ACTUAL |
| MECHANICAL EQUIPMENT ITSELF, THE EXTERIOR CABINETRY. |
| |
| 7A-B) COMPLIED. |
| |
| 8) COMPLIED. |
| |
| 9) COMPLIED. |
| |
| 10)2ND REQUEST, AT CONTRACTORS OWN RISK!!! SHEET S-4 |
| PLEASE INDICATE COMPLIANCE WITH 1802.2.1 QUESTIONABLE |
| SOIL. WHERE THE SAFE-SUSTAINING POWER OF THE SOIL IS IN |
| DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT |
| SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING |
| OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION |
| BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE |
| PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . |
| |
| 11)COMPLIED |
| |
| 12) 2ND REQUEST, SHEET S-4 CODES AND SPECIFICATIONS ALL |
| WORK SHALL BE IN ACCORDANCE WITH 2007 FBC HIGH WIND |
| VELOCITY ZONE, PLEASE NOT THE HIGH VELOCITY WIND ZONE |
| DESIGNATION IS ONLY TO BE USED FOR DADE AND BROWARD |
| COUNTIES, THE CITY OF WEST PALM BEACH IS LOCATED IN THE |
| HIGH WIND DEBRIS REGION PLEASE REVIEW FIGURE 1609. THE |
| WIND DESIGN FOUND ON SHEET S-2 INDICATES 146MPH, |
| EXPOSURE "C" WHICH IS A DADE AND BROWARD REQUIREMENT |
| FOR THE HIGH WIND VELOCITY ZONE. IF THE DESIGNER |
| WHISHES TO DESIGN TO THIS MORE STRINGENT REQUIREMENT, |
| THEN THE ASSOCIATED HIGHER POSITIVE & NEGATIVE |
| PRESSURES MUST BE USED IN THE WIND DESIGN. |
| |
| 12A-C) COMPLIED. |
| |
| 13) SEE NOTE# 4 SAME QUESTION. |
| |
| 14) 2ND REQUEST, PROVIDE INFORMATION ON THE WALK-IN |
| COOLERS AND FREEZERS. 2603.4.1.2 COOLER AND FREEZER |
| WALLS. FOAM PLASTIC INSTALLED IN A MAXIMUM THICKNESS OF |
| 10 INCHES (254 MM) IN COOLER AND FREEZER WALLS SHALL: |
| 1. HAVE A FLAME SPREAD INDEX OF 25 OR LESS AND A |
| SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450, WHERE |
| TESTED IN A MINIMUM 4 INCH (102 MM) THICKNESS. |
| 2. HAVE FLASH IGNITION AND SELF-IGNITION TEMPERATURES |
| OF NOT LESS THAN 600?F AND 800?F (316?C AND 427?C), |
| RESPECTIVELY. |
| 3.HAVE A COVERING OF NOT LESS THAN 0.032-INCH (0.8 MM) |
| ALUMINUM OR CORROSION-RESISTANT STEEL HAVING A BASE |
| METAL THICKNESS NOT LESS THAN 0.0160 |
| INCH (0.4 MM) AT ANY POINT. |
| 4. BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM. WHERE |
| THE COOLER OR FREEZER IS WITHIN A BUILDING, BOTH THE |
| COOLER OR FREEZER AND THAT PART OF THE |
| BUILDING IN WHICH IT IS LOCATED SHALL BE SPRINKLED. |
| |
| 2603.4.1.3 WALK-IN COOLERS. IN NON-SPRINKLED BUILDINGS, |
| FOAM PLASTIC HAVING A THICKNESS THAT DOES NOT EXCEED 4 |
| INCHES (102 MM) AND A MAXIMUM |
| FLAME SPREAD INDEX OF 75 IS PERMITTED IN WALK-IN |
| COOLERS OR FREEZER UNITS WHERE THE AGGREGATE FLOOR AREA |
| DOES NOT EXCEED 400 SQUARE FEET (37 M 2 ) AND THE FOAM |
| PLASTIC IS COVERED BY A METAL FACING NOT LESS THAN |
| 0.032-INCH-THICK (0.81 MM) ALUMINUM OR |
| CORROSION-RESISTANT STEEL HAVING A MINIMUM BASE METAL |
| THICKNESS OF 0.016 INCH (0.41 MM). A THICKNESS OF UP TO |
| 10 INCHES (254 MM) IS PERMITTED WHERE PROTECTED BY A |
| THERMAL BARRIER. |
| |
| 15) SHEET A-7 INDICATES VARIOUS SECTIONS THROUGH THE |
| STRUCTURE WITH FINISHES( 106.3.5 MINIMUM PLAN REVIEW |
| CRITERIA FOR COMMERCIAL BUILDINGS ; |
| 15A) PLANS ARE NOT COMPLETE AS TO INTERIOR FINISHES OF |
| ROOMS |
| |
| 15B) COMPLIED. |
| |
| 15C) A V-B BUILDING TYPE WILL NOT REQUIRE FIRE RATED |
| CEILINGS. THE QUESTION WAS WILL THEY BE NEEDED, NO THEY |
| WOULD NOT BE REQUIRED BECAUSE OF THE AREA INCREASES |
| PROVIDED BY THE NFPA 13 SPRINKLER SYSTEM.. |
| |
| 15D) COMPLIED. |
| |
| 16) PROVISO: TRUSS PLANS WERE NOT SUBMITTED, PLANS FAIL |
| TO PROVIDE LOADS TO BE RESISTED, HORIZONTAL, LATERAL |
| AND GRAVITY LOADS. |
| |
| 17) NEW COMMENT: THIS BUILDING WILL REQUIRE 2 EXITS AT |
| LEAST 1/3RD THE DISTANCE APART. 1015.2.1. THE REAR |
| DOORS AS IS CAN NOT BE USED AS AN EXIT SINCE THEY LEAD |
| INTO A STORAGE OCCUPANCY. |
| |
| 18) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| NOTICE. |
| |
| OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| - 5:00 PM. |
| |
| JIM WITMER C. B. O. |
| COMMERCIAL COMBINATION PLAN REVIEW |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| SURVEY: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |