2009-09-09 11:45:55 | BUILDING PLAN REVIEW |
| PERMIT: 09080604 |
| ADD: 519 CLEMATIS ST. |
| CONT: SEC |
| TEL: (561)797-6007 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| 09-09-09 |
| ACTION: DENIED |
| |
| 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| BUILDING WITH 2009 SUPPLEMENTS. |
| |
| PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING |
| BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO |
| WHAT LEVEL ALTERATION WILL BE COMPLETED UNDERTHIS |
| PERMIT. |
| 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE |
| OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| SECTIONS 403, 404 AND 405 OF THIS CODE. |
| |
| 2) PLANS ARE DEFICIENT IN THE FOLLOWING ITEMS, 106.3.5 |
| MINIMUM PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS: |
| 106.3.5(2) OCCUPANCY GROUP AND SPECIAL OCCUPANCY |
| REQUIREMENTS SHALL BE DETERMINED. |
| |
| (3) MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED |
| (SEE TABLE 503). |
| |
| (4) FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL |
| INCLUDE THE FOLLOWING COMPONENTS: |
| FIRE-RESISTANT SEPARATIONS TABLE 601 |
| |
| (5) FIRE SUPPRESSION SYSTEMS, ARE THER FIRE SPRINKLERS? |
| 903 |
| PLANS DO NOT PROVIDE FIRE EXTINGUISHER LOCATIONS 906.1 |
| |
| (6) LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL |
| INCLUDE THE FOLLOWING REQUIREMENTS: |
| OCCUPANT LOAD AND EGRESS CAPACITIES |
| |
| (7) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD TABLE 1004.1.1 |
| MEANS OF EGRESS / EXIT ACCESS 1015/ AISLE ACCESSWAYS |
| 1014.4.3.3 |
| |
| (8) INTERIOR REQUIREMENTS SHALL INCLUDE THE FOLLOWING: |
| INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) |
| 803.1/ TABLE 803.5 |
| SANITATION 1210.2 |
| |
| (9) ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE |
| FOLLOWING: |
| ACCESSIBLE ROUTE BOTH FOR THE INTERIOR AND PATIO DECK |
| RESTROOMS |
| |
| 3) SHEET A.02 INDICATESA STALL WITHIN THE MENS |
| RESTROOM, THE NEW WORK SHEET A.03 INDICATES THE STALL |
| NOW DOES NOT HAVE A TURNING RADIUS WITHIN THE STALL, |
| PLEASE REVIEW 11-4.1.6 ACCESSIBLE BUILDINGS- |
| ALTERATIONS (1) |
| A) NO ALTERATION SHALL BE UNDERTAKEN WHICH DECREASES OR |
| HAS THE EFFECT OF DECREASING ACCESSIBILITY OR USABILITY |
| OF A BUILDING OR FACILITY BELOW THE REQUIREMENTS FOR |
| NEW CONSTRUCTION AT THE TIME OF ALTERATION. |
| |
| (B) IF EXISTING ELEMENTS, SPACES, OR COMMON AREAS ARE |
| ALTERED, THEN EACH SUCH ALTERED ELEMENT, SPACE, |
| FEATURE, OR AREA SHALL COMPLY WITH THE APPLICABLE |
| PROVISIONS OF SECTION 11-4.1.1 TO SECTION 11-4.1.3, |
| MINIMUM REQUIREMENTS FOR NEW CONSTRUCTION. IF THE |
| APPLICABLE PROVISION FOR NEW CONSTRUCTION REQUIRES THAT |
| AN ELEMENT, SPACE, OR COMMON AREA BE ON AN ACCESSIBLE |
| ROUTE, THE ALTERED ELEMENT, SPACE, OR COMMON AREA IS |
| NOT REQUIRED TO BE ON AN ACCESSIBLE ROUTE EXCEPT AS |
| PROVIDED IN SECTION 11-4.1.6(2), ALTERATIONS TO AN AREA |
| CONTAINING A PRIMARY FUNCTION. |
| |
| (C) IF ALTERATIONS OF SINGLE ELEMENTS, WHEN CONSIDERED |
| TOGETHER, AMOUNT TO AN ALTERATION OF A ROOM OR SPACE IN |
| A BUILDING OR FACILITY, THE ENTIRE SPACE SHALL BE MADE |
| ACCESSIBLE. |
| |
| 4) PLEASE ALSO PROVIDE A FLOOR PLAN INDICATING |
| COMPLIANCE WITH : |
| 11-5.1 GENERAL. EXCEPT AS SPECIFIED OR MODIFIED IN THIS |
| SECTION, RESTAURANTS AND CAFETERIAS SHALL COMPLY WITH |
| THE REQUIREMENTS OF SECTION 11-4.1 TO SECTION 11-4.35. |
| WHERE FIXED TABLES (OR DINING COUNTERS WHERE FOOD IS |
| CONSUMED BUT THERE IS NO SERVICE) ARE PROVIDED, AT |
| LEAST 5 PERCENT, BUT NOT LESS THAN ONE, OF THE FIXED |
| TABLES (OR A PORTION OF THE DINING COUNTER) SHALL BE |
| ACCESSIBLE AND SHALL COMPLY WITH SECTION 11-4.32 AS |
| REQUIRED IN SECTION 11-4.1.3(18). ETWEEN THE SMOKING |
| AND NONSMOKING AREAS. IN NEW CONSTRUCTION, AND WHERE |
| PRACTICABLE IN ALTERATIONS, ACCESSIBLE FIXED TABLES (OR |
| COUNTERS) SHALL BE DISTRIBUTED THROUGHOUT THE SPACE OR |
| FACILITY. |
| |
| 11-5.2 COUNTERS AND BARS. WHERE FOOD OR DRINK IS SERVED |
| AT COUNTERS EXCEEDING 34 INCHES (865 MM) IN HEIGHT FOR |
| CONSUMPTION BY CUSTOMERS SEATED ON STOOLS OR STANDING |
| AT THE COUNTER, A PORTION OF THE MAIN COUNTER WHICH IS |
| 60 INCHES (1525 MM) IN LENGTH MINIMUM SHALL BE PROVIDED |
| IN COMPLIANCE WITH SECTION 11-4.32 OR SERVICE SHALL BE |
| AVAILABLE AT ACCESSIBLE TABLES WITHIN THE SAME AREA. |
| |
| 11-5.3 ACCESS AISLES. ALL ACCESSIBLE FIXED TABLES SHALL |
| BE ACCESSIBLE BY MEANS OF AN ACCESS AISLE AT LEAST 36 |
| INCHES (915 MM) CLEAR BETWEEN PARALLEL EDGES OF TABLES |
| OR BETWEEN A WALL AND THE TABLE EDGES. |
| |
| 11-5.4 DINING AREAS. IN NEW CONSTRUCTION, ALL DINING |
| AREAS, INCLUDING RAISED OR SUNKEN DINING AREAS, |
| LOGGIAS, AND OUTDOOR SEATING AREAS, SHALL BE |
| ACCESSIBLE. IN ALTERATIONS, ACCESSIBILITY TO RAISED OR |
| SUNKEN DINING AREAS, OR TO ALL PARTS OF OUTDOOR SEATING |
| AREAS IS NOT REQUIRED PROVIDED THAT THE SAME SERVICES |
| AND DECOR ARE PROVIDED IN AN ACCESSIBLE SPACE USABLE BY |
| THE GENERAL PUBLIC AND ARE NOT RESTRICTED TO USE BY |
| PEOPLE WITH DISABILITIES. |
| |
| 5) DESIGN LOADS SHEET A.04 & A.05 BOTH INDICATE A |
| 120MPH / 3SECOND GUST, PLEASE REVIEW FIGURE 1609 THE |
| CITY OF WEST PALM BEACH IS ENTIRELY LOCATED WITHIN A |
| 140 MPH WIND ZONE, PLEASE UPDATE PLANS. |
| |
| 6) DESIGN LOADS SHEET A.04 & A.05 BOTH INDICATE FLOOR |
| LOADS OF 40 PSF LIVE LOADS PLEASE REVIEW TABLE 1607.1 |
| DINING ROOMS & RESTARAUNTS OF 100 PSF, OR ASSEMBLY WITH |
| MOVABLE SEATS 100 PSF. |
| PLEASE PROVIDE ADDITIONAL INFORMATION ON THE TYPE OF |
| FLOOR SYSTEM, PLANS APPEAR TO INDICATE A FLOOR TRUSS |
| SYTEM? |
| |
| 7) BOTH A.05 & S1 BOTH INDICATE A NEW OPENING ON THE |
| SIDE OF THE BUILDING WITH A PAIR OF GLAZED OPENINGS & |
| TWO SIDELIGHTS. THE PRODUCT SUBMITTED FL 10356-R1 IS |
| ONLY FOR A PAIR OF DOORS NON-IMPACT. MISSING PRODUCT |
| APPROVALS ARE: |
| 7A) FIXED OR STOREFRONT WINDOWS/ SIDELIGHTS |
| 7B) VERTICAL MULLION |
| 7C ) STORM SHUTTTERS/ PANELS |
| |
| 8) STORM SHUTTERS PLEASE PROIDE THE FOLLOWING: FL BLD |
| CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 & EXIST |
| BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE |
| INSTALLATION |
| SCHEDULE SUMMARIZING & IDENTIFYING OPENING SIZES, STORY |
| HEIGHTS, UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT |
| STORM BAR REINFORCING REQUIREMENTS, WALL PRESSURE |
| ZONES, SLAT TYPES, ETC., SHALL BE SUBMITTED AT TIME OF |
| PERMIT APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT |
| ISSUANCE. |
| |
| 9) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITTING BY THE DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| NOTICE. |
| |
| OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| - 5:00 PM. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| SURVEY: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |