2009-09-17 16:47:55 | ****CORRECTIONS**** | | REVISION #1 | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | THIS PERMIT WAS ISSUED WITH PROVISOS WHICH WHERE NOT | | ADDRESSED: | | | | 1. REVISE STRUCTURAL DETAILS: | | SHEATHING TO COMPLY WITH MINIMUM REQUIREMENT OF FBC R | | TABLE 803.1 - SHEATHING WAS CHANGED FROM 7/16" OSB TO | | 5/32. IT IS NOT CLEAR HOW MAKING THE SHEATHING LESS | | THAN 1/4" MAKES IT COMPLY WITH THE 1/2" MINIMUM | | REQUIREMENT. PLEASE HAVE THE ENGINEER CONTACT ME IF | | CLARIFICATION IS REQUIRED. | | | | ENGINEER TO INCORPORATE CHANGES INTO PLAN - THIS WAS | | NOT ADDRESSED. PLEASE HAVE ENGINEER INCORPORATE THE | | CHANGES TO THE DESIGN INTO HIS PLAN. | | | | |
|