Plan Review Notes
Plan Review Notes For Permit 09060761
Permit Number 09060761
Review Stop P
Sequence Number 1
Notes
Date Text
2009-07-06 15:11:29DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
 FBC-2007 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. SHTS DT-1, DT-2, LS-1 THRU LS-4, LD-1, LD-2, LP-1
 THRU LP-5 & IR-1 REQUIRES A FIRM LICENSE NUMBER,
 (CERTIFICATE OF AUTHORIZATION), AND PHONE NUMBER IN THE
 TITLE BLOCK OF EACH SHEET. ALSO THE DATE THE SIGNATURE
 AND SEAL ARE AFFIXED SHALL BE INDICATED ON THE SEAL.
 FAC 61G10-11.010(1)(2) & FS 481.219, 481.306.
  
 2. SHT EP1.0 WASTE RISER DIAGRAM. THE FITTING
 DOWNSTREAM OF THE WATER CLOSETS DOES NOT GUIDE THE
 SEWAGE & WASTE IN THE DIRECT OF FLOW AS REQUIRED IN
 SECTION 706.3. PLEASE CORRECT RISER DIAGRAM.
  
 3. SHT EP1.0 NOTE #1 OF THE WATER RISER. AIR CHAMBERS
 ARE NOT APPROVED. PLEASE DELETE FROM NOTE. PDI-WH 201.
  
 4. SUBMIT AN ISOMETRIC RISER DIAGRAM FOR THE WATER
 PIPING. SHOW ALL PIPE SIZES, VALVES ETC. SECTION
 106.3.5.1.3(3)(10)(13). SECTION 601.1.
  
 5. ALL SHEETS DESIGNED BY A DESIGN PROFESSIONAL SHALL
 BE SIGNED, SEALED AND DATED BY THE DESIGN PROFESSIONAL.
 SECTION 106.1. SOME SHEETS ARE NOT SIGNED, SEALED OR
 DATED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  