Plan Review Notes For Permit 09060526 |
Permit Number |
09060526 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2009-07-27 12:03:04 | BUILDING PROVISO: | | STUCCO OVER WOOD FRAME CONSTRUCTION REQUIRES A BOND | | BRAKER. 1404.2.1 WHERE CEMENT PLASTER (STUCCO) IS TO BE | | APPLIED TO LATH OVER FRAME CONSTRUCTION, MEASURES SHALL | | BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PLASTER | | AND THE WATER RESISTIVE BARRIER. A BOND BREAK SHALL BE | | PROVIDED BETWEEN THE WATER RESISTIVE BARRIER AND THE | | CEMENT PLASTER (STUCCO) CONSISTING OF ONE OF THE | | FOLLOWING: | | | | 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER OR | | | | 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER | | OVER AN APPROVED PLASTIC HOUSE WRAP, OR | | | | 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | |
|