1 |
|
Notes |
Date |
Text |
2009-06-18 18:16:00 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. THE PRODUCT REQUIRES 3000PSI CONCRETE, SEE PAGE 1. | | FOR OPENINGS WITH A FLOOR MOUNT, PLEASE NOTE THAT | | RESIDENTIAL SLABS ARE TYPICALLY POURED AT 2500PSI; HOW | | HAVE YOU DETERMINED THAT THE CONCRETE MEETS THE MINIMUM | | STRENGTH? YOU MAY USE ANCHOR SPACING FOR MASONRY/BLOCK | | IN LIEU OF PROVIDING EVIDENCE THAT THE CONCRETE MEETS | | 3000PSI REQUIREMENT. | | | | **UPON REQUEST (TELEPHONE CALL), PLAN WILL BE REDLINED | | TO REVISE ANCHOR SPACING FOR OPENING #7 TO BE 3" | | BOTTOM** | | |
|