Plan Review Notes
Plan Review Notes For Permit 09060501
Permit Number 09060501
Review Stop B
Sequence Number 1
Notes
Date Text
2009-06-18 18:16:00****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. THE PRODUCT REQUIRES 3000PSI CONCRETE, SEE PAGE 1.
 FOR OPENINGS WITH A FLOOR MOUNT, PLEASE NOTE THAT
 RESIDENTIAL SLABS ARE TYPICALLY POURED AT 2500PSI; HOW
 HAVE YOU DETERMINED THAT THE CONCRETE MEETS THE MINIMUM
 STRENGTH? YOU MAY USE ANCHOR SPACING FOR MASONRY/BLOCK
 IN LIEU OF PROVIDING EVIDENCE THAT THE CONCRETE MEETS
 3000PSI REQUIREMENT.
  
 **UPON REQUEST (TELEPHONE CALL), PLAN WILL BE REDLINED
 TO REVISE ANCHOR SPACING FOR OPENING #7 TO BE 3"
 BOTTOM**
  