Plan Review Notes For Permit 09060411 |
Permit Number |
09060411 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2009-06-16 16:25:45 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- ACCORDING TO APPROVED ASSEMBLIES ON SHEET 3 OF | | UNDERLAYMENT NOA 07-1130.01 SUBMITTED THIS UNDERLAYMENT | | CAN ONLY BE USED WHEN THE APPROVED ROOFING ASSEMBLY | | ALLOWS AN ASTM D 1970 UNDERLAYMENT. ROOFING ASSEMBLY | | SUBMITTED DOESN'T ALLOW THIS TYPE OF UNDERLAYMENT. | | PROVIDE UNDERLAYMENT PRODUCT APPROVAL THAT IS ALLOWED | | BY THE ROOFING ASSEMBLY SUBMITTED. | | | | 2- LIMITATION #6 ON SHEET 4 OF UNDERLAYMENT NOA | | 07-1130.01 SUBMITTED STATES THAT MAXIMUM ROOF PITCH IS | | 4:12. PERMIT APPLICATION STATES 9:12 PITCH. THIS | | UNDERLAYMENT DOESN'T WORK FOR PROPOSED INSTALLATION. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|