Notes |
Date |
Text |
2009-06-12 10:04:44 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. PROVIDE DOOR SIZE AND DISTANCE FROM DOOR TO OUTSIDE | | CORNER OF BUILDING ON THE FLOOR PLAN. DESIGN PRESSURES | | CANNOT BE DETERMINED WITHOUT THIS INFORMATION. FBC | | R301, ASCE7-05. | | | | 2. PLEASE CLARIFY; APPLICATION STATES THAT THIS IS AN | | IMPACT FRAME WITH IMPACT INSERTS, PRODUCT APPROVAL | | STATES THIS IS NON IMPACT. PLEASE CLARIFY SCOPE OF WORK | | FBC*106, FBC R301.2.1.2. BASED ON HOUSE CONSTRUCTION | | DATE, THIS RESIDENCE SHOULD HAVE EXISTING IMPACT | | PROTECTION. HOWEVER, IF THE CONTRACTOR STATES THAT HE | | IS INSTALLING IMPACT DOORS, IMPACT DOORS ARE TO BE | | INSTALLED. PLEASE EITHER REVISE THE APPLICATION OR | | PROVIDE IMPACT DOOR PRODUCT APPROVALS. | | |
|