Plan Review Notes For Permit 09060228 |
Permit Number |
09060228 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2009-06-15 10:23:22 | RESIDENTIAL (R2) RE-ROOF, BUILDING REVIEW CHECKLIST. | | 2007 FBC WITH 2009 REVISIONS. | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | REQUIRED BY GENERAL LIMITATION #7 ON SHEET 14 OF NOA | | 07-1018.10 SUBMITTED. | | ***NOTE: ACCORDING TO 2009 REVISIONS TO FBC 2007 THIS | | BUILDING IS LOCATED ON EXPOSURE "C". DESIGN | | PROFESSIONAL TO HAVE THIS EXPOSURE IN CONSIDERATION | | WHEN DOING THE RAS 117 CALCULATIONS. | | | | 2- CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO | | BE INSTALLED TO VERIFY COMPLIANCE WITH THE CALCULATED | | DESIGN PRESSURES. NOA SUBMITTED SHOWS TWO DIFFERENT | | ASSEMBLIES. ONE ON PAGE 7 AND ONE ON PAGE 9. SELECT | | ONLY ONE ASSEMBLY AND PROVIDE RESPECTIVE RAS 117 | | CALCULATIONS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|