Plan Review Notes For Permit 09060176 |
Permit Number |
09060176 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2009-06-12 11:15:34 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. IMPACT PROTECTION MUST BE LARGE MISSILE IMPACT, FBC | | R 301.2.1.2. A SMALL MISSILE IMPACT WINDOW PRODUCT | | APPROVAL WAS SUBMITTED. | | | | 2. PLEASE CLARIFY, SKYLIGHTS ARE SHOWN ON THE PLAN. DO | | YOU MEAN CLERESTORY WINDOWS? WILL THESE "SKYLIGHTS" BE | | INSTALLED IN A VERTICAL (WALL) OR HORIZONTAL (ROOF) | | OPENING? BY DEFINITION, SKYLIGHTS ARE INSTALLED IN THE | | ROOF, AND SHOULD HAVE A PRODUCT APPROVAL WITH THE | | DESCRIPTION OF "SKYLIGHT," AND TESTED FOR A HORIZONTAL | | (ROOF) APPLICATION. A "WINDOW" IS TESTED IN A WALL AND | | IS NOT INTENDED FOR HORIZONTAL USE UNLESS ENGINEERED IN | | THAT MANNER. A CLERESTORY WINDOW IS VERTICAL BUT | | TYPICALLY INSTALLED JUST BELOW THE EAVE, AND A "WINDOW" | | PRODUCT APPROVAL WOULD BE PERMITTED IN THAT | | APPLICATION. PLEASE CLARIFY "SKYLIGHT" INSTALLATION. | | | | | | | | |
|