2009-08-07 11:33:07 | BUILDING PLAN REVIEW |
| PERMIT: 09060175 |
| ADD: 1302 PARKER AVE |
| CONT: PLAN REVIEW/ TBA |
| TEL: (561)706-0429 / ALBERT MARINCLLO |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| AUGUST 07/2009 |
| 2ND REVIEW |
| ACTION: DENIED |
| |
| 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| BUILDING WITH 2009 SUPPLEMENTS. |
| |
| 2) PLANS ARE CURRENTLY IN AS A PLAN REVIEW, BUT WHEN |
| THEY ARE SUBMITTED FOR PERMIT, THEY WILL NEED TO BE |
| SIGNED AND SEALED. |
| PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| FL ADMIN CODE 61G15-23.002 ENGINEERS |
| FL ADMIN CODE 61G16.003 ARCHITECTS |
| |
| 3) COMPLIED. |
| |
| 4) 2ND REQUEST, SHEET GC-503 GENERAL NOTE# 2 INDICATES |
| A SOILS REPORT BY DUNKLEBURGER ENGINEERING AND TESTING |
| WAS COMPLETED JULY 16, 2008, PLEASE SUPPLY (2) RAISED |
| SEAL ORIGINALS. |
| |
| 5) 2ND REQUEST, THERE ARE STRUCTURES FOUND ON THIS |
| SHEET STRUCTUREE WITH WEIR AS WELL AS HANDRAILS, |
| ALTHOUGH THE WEIR WILBE LOW GRADE THE HANDRAIL WILL BE |
| ABOVE GRADE AND SUBJECT TO WIND. SHEET GC-502 DOES NOT |
| INDICATE WIND DESIGN CRITERIA:1603.1.4 WIND DESIGN |
| DATA. SHEET E-501 ALSO HAS LIGHT POLES THAT WILL NEED |
| TO HAVE WHAT WIND DESIGN CRITERIA WOULD HAVE BEEN USED |
| IN CALCULATING IF THEY WILL WITHSTAND 140 MPH WIND, IF |
| DERATING FACTORS WERE USED. |
| |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| BUILDING: |
| 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| (KM/HR). |
| |
| 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| |
| 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| DIRECTION SHALL BE INDICATED. |
| |
| 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| |
| |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| SURVEY: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |