2009-07-08 08:13:16 | BUILDING PLAN REVIEW |
| PERMIT: 09060175 |
| ADD: 1302 PARKER AVE |
| CONT: PLAN REVIEW/ TBA |
| TEL: (561)706-0429 / ALBERT MARINCLLO |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| BUILDING WITH 2009 SUPPLEMENTS. |
| |
| 2) PLANS ARE CURRENTLY IN AS A PLAN REVIEW, BUT WHEN |
| THEY ARE SUBMITTED FOR PERMIT, THEY WILL NEED TO BE |
| SIGNED AND SEALED. |
| PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| FL ADMIN CODE 61G15-23.002 ENGINEERS |
| FL ADMIN CODE 61G16.003 ARCHITECTS |
| |
| 3) OEST IS MISSING THEIR CERTIFICATE OF AUTHORIZATION |
| IN THE TITLEBLOCK. |
| 471.023 F.S. CERTIFICATE OF AUTHORIZATION. THE TITLE |
| BLOCK FOR ANY SHEET BEARING THE NAME OF AN ENGINEER |
| PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A |
| PARTNERSHIP, OFFERING ENGINEERING SERVICES, SHALL |
| INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER. ADD |
| THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND. |
| |
| 4) SHEET GC-003 GENERAL NOTE# 2 INDICATES A SOILS |
| REPORT BY DUNKLEBURGER ENGINEERING AND TESTING WAS |
| COMPLETED JULY 16, 2008, PLEASE SUPPLY (2) RAISED SEAL |
| ORIGINALS. |
| |
| 5) SHEET GC-002 DOES NOT INDICATE WIND DESIGN |
| CRITERIA:1603.1.4 WIND DESIGN DATA. |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| BUILDING: |
| 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| (KM/HR). |
| |
| 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| |
| 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| DIRECTION SHALL BE INDICATED. |
| |
| 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| |
| 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION |
| OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| PROFESSIONAL. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| SURVEY: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |