Date |
Text |
2009-06-05 15:41:17 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2004 |
| FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| |
| 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED |
| FAC9B72. LOCAL PRODUCT APPROVAL APPLICATION AVAILABLE |
| AT WWW.FLORIDABUILDING.ORG OR HTTP://WWW.WPB.ORG/CONSTR |
| UCTION/PDF/PRODUCT%20APPROVAL.PDF. PLEASE COMPLETE THE |
| APPLICATION WITH ALL PERTINENT INFORMATION, INCLUDING |
| HOW QUALITY ASSURANCE WILL BE ADDRESSED (A LETTER FROM |
| THE ENGINEER STATING THAT SHE WILL DO AN INSPECTION IS |
| ONE METHOD OF ADDRESSING QUALITY ASSURANCE). |
| |
| 2. PROVIDE A CONTRACT FOR THIS JOB. VALUE IS TO INCLUDE |
| LABOR AND MATERIALS. FBC*108. |
| |
| 3. PLEASE CLARIFY DESIGN CRITERIA. IF THIS IS |
| ASSOCIATED WITH THE MASTER PERMIT AS NOTED ON THE |
| APPLICATION, AND WAS SHOWN ON THE PLANS FOR 08010413, |
| THEN THE DESIGN CRITERIA SHOULD BE FBC2004 AND ASCE7-02 |
| AND REVIEW BY DESIGNER OF RECORD IS REQUIRED FBC*103. |
| IF THIS IS A STAND-ALONE PERMIT INDEPENDENT OF |
| 08010413, THEN THE DESIGN CRITERIA IS FBC2007 WITH 2009 |
| SUPPLEMENTS AND ASCE7-05. ENGINEER HAS STATED FBC2004 |
| AND ASCE7-05 AS DESIGN CRITERIA; NOT CONSISTENT. |
| |
| 4. IF ASCE7-05 IS USED AS DESIGN CRITERIA, PLEASE |
| PROVIDE JUSTIFICATION FOR EXPOSURE B PRESSURES. THIS |
| PARCEL APPEARS TO BE WITHIN 1500' OF EXPOSURE C |
| ROUGHNESS CONDITIONS (INTRACOASTAL). |
| |
| |
| |
| |
| |
| |