Plan Review Notes
Plan Review Notes For Permit 09060005
Permit Number 09060005
Review Stop B
Sequence Number 1
Notes
Date Text
2009-06-19 14:03:50BUILDING PLAN REVIEW
 PERMIT: 09060005
 ADD: 1801 S FLAGLER DR UNIT 1411
 CONT: MARYJULI CONSTRUCTION
 TEL: (561)386-6032
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 2) SHEET # 1 MISCELLANEOUS NOTE#1 INDICATES THIS TO BE
 A R-4 OCCUPANCY WHEREAS IN THE LISTED ON THE SAME SHEET
 CONSTRUCTION INFORMATION INDICATES A R2 OCCUPANCY.
 TABLE 803.5.
  
 3) SHEET 4 INDICATES THE USE OF SOFFITS BUT THERE IS NO
 INFORMATION AS TO MATERIALS, FRAMING OR ATTACHMENT TO
 THE DECK ABOVE? ADDITIONAL INFORMATION REQUIRED
 106.1.2.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.