2009-06-04 09:05:33 | RESIDENTIAL (R2) DOOR REPLACEMENT, BUILDING REVIEW | | CHECKLIST. | | REVIEW UNDER 2007 FBC WITH 2009 REVISIONS. | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | FLORIDA STATUTE. | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | 2- PRODUCT APPROVAL FL11089 SUBMITTED DOESN'T MEET THE | | DESIGN PRESSURES CALCULATED BY TARNOWSKI ENGINEERING. | | PROVIDE PRODUCT APPROVAL THAT MEETS BOTH POSITIVE AND | | NEGATIVE PRESSURES AS CALCULATED BY THE ENGINEER OF | | RECORD. | | | | 3- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) THE DOOR PRODUCT APPROVAL AS | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. | | | | 4- ENGINEER OF RECORD TO PROVIDE STRUCTURAL DETAILS FOR | | ATTACHMENT OF DOORS TO I BEAM AND TO CORNER STEEL | | COLUMN. PRODUCT APPROVAL DOESN'T PROVIDE ATTACHMENT TO | | STEEL. THEREFORE THIS NEEDS TO BE PROVIDED BY THE | | ENGINEER OF RECORD AS REQUIRED BY GENERAL NOTE #4 ON | | PRODUCT APPROVAL SHEET 1 OF DRAWING #FWI0094 SUBMITTED | | AND SEC. 106.1.2 CITY AMENDMENTS TO FBC . | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|