2009-05-12 17:08:44RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009
 REVISIONS.
  
 1- ENGINEER TO REVISE RAS 117 CALCULATIONS:
 A) BUILDING IS LOCATED ON EXPOSURE "C" NOT "B" AS
 REQUIRED BY 2009 REVISIONS TO THE 2007 FLORIDA
 RESIDENTIAL CODE. REVISE CALCULATED DESIGN PRESSURES
 ACCORDINGLY. SEE SECTIONS R301.2.1.4 THRU R301.2.1.4.2
 OF 2009 REVISIONS.
  
 B) NOA 06-0410.06 FILE IS CLOSED BY MIAMI-DADE COUNTY
 PRODUCT APPROVAL DIVISION. SEE ATTACHED COPY FROM DADE
 COUNTY WEBSITE. NEED TO PROVIDE CURRENT PRODUCT
 APPROVAL.
  
 2- FLAT ROOF PRODUCT APPROVAL FL1654 SUBMITTED ALSO
 REQUIRES CALCULATIONS FOR NAIL ENHANCING DONE BY A
 DESIGN PROFESSIONAL. SEE NOTE #6 OF THE NOTES THAT
 APPLY TO THE SELECTED SYSTEM. SEE ATTACHED COPY FROM
 FLORIDA PRODUCT APPROVAL FL1654-R4.
 **NOTE: USE EITHER THE FLORIDA PRODUCT APPROVAL OR
 CURRENT NOA.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712