Date |
Text |
2009-05-21 15:26:49 | DENIED |
| REFERENCE: |
| FBC-2007 W/2009 SUPPLEMENTS |
| FBC-2007 EXISTING BUILDING |
| FBC-2007 PLUMBING |
| FBC-2007 CHAPTER 1 |
| FBC-2007 CHAPTER 11 |
| |
| 1. SHT A-1 THE PROPOSED TOILET ROOM SHALL BE |
| ACCESSIBLE. THE MINIMUM WIDTH FOR AN ACCESSIBLE TOILET |
| ROOM IS 5'3" FINISHED WIDTH. THE PLANS SHOW 5'0". |
| SECTION 405.3.1 & FIG. 28. |
| |
| 2. SHT A-1 SHOW THE TURNING AREA IN THE ACCESSIBLE |
| TOILET ROOM. SECTION 11-4.22.3. |
| |
| 3. SHT A-1. BATHROOM NOTES #3 INDICATES THE GRAB BAR |
| BEHIND THE W/C TO BE 24 INCHES LONG AND MAXIMUM 12" |
| FROM THE CORNER. THE GRAB BAR BEHIND THE W/C IS |
| REQUIRED TO BE A MINIMUM 36" LONG AND A MAXIMUM 6" FROM |
| THE CORNER. SEE SECTION 11-4.16.4. |
| |
| 4. SUBMIT A SANITARY ISOMETRIC RISER DIAGRAM SHOWING |
| ALL PIPE SIZES, TRAPS, VENTS, POINTS OF CONNECTION & |
| POINTS OF TERMINATION. SECTION 106.3.5.1.3(4)(6)(13). |
| |
| 5. SUBMIT A WATER ISOMETRIC RISER DIAGRAM SHOWING ALL |
| PIPE SIZES, VALVES, WATER HAMMER ARRESTORS, POINTS OF |
| CONNECTION ETC. SECTIONS 106.3.5.1.3(3)(5)(8)(13) & |
| 604.9. |
| |
| 6. PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED. |
| PLEASE SHOW THE LOCATION OF THE REQUIRED DRINKING |
| FOUNTAIN. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| ONE SET OF THEM LOOSELY ON TOP OF THE |
| COLLATED PLANS TO BE REVIEWED. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| REVIEW BY KEN STEVENS |
| (561) 805-6721 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |
| |
| |
| |