Plan Review Notes
Plan Review Notes For Permit 09050098
Permit Number 09050098
Review Stop B
Sequence Number 1
Notes
Date Text
2009-05-08 11:27:09ROOFING NOA INFORMATION:
 JOHNS MANVILLE CORP
 NOA: 07-0228.04
 PAGE 7:
 MEMBRANE TYPE SBS
 DECK TYPE 21: STEEL, INSULATED
 DECK DESCRIPTION: 18-22 GA. STEEL
 SYSTEM TYPE B(1)
 REQUIRED INSULATION FROM THE ENERGY INPUT DATA REPORT
 R=20.4
 ENERGY 3 REQUIRES 3.1 INCHES R=19.00
 RETRO-FIT BD 0.5 INCHES R= 1.32
 R=20.32 PLUS ROOFING
 REQUIRES INHANCED FASTENING LIMITATION# 7 BY ON TARGET
 ENGINEERING, INC.
 ZONES 2 (71.685) & ZONE 3 9107.89)