Plan Review Notes For Permit 09050076 |
Permit Number |
09050076 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2009-07-22 22:25:02 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. PLEASE PROVIDE EVIDENCE THAT THIS PROPERTY IS | | GREATER THAN 1500' FROM THE INTERCOASTAL. THE | | CONTRACTOR PROVIDED A STATEMENT THAT THE PROPERTY IS | | GREATER THAN 1500', AND THE PERMIT WAS ISSUED BASED ON | | THAT STATEMENT. HOWEVER, MEASUREMENTS PROVIDED BY OUR | | GIS SHOWS THAT THIS PROPERTY IS APPROXIMATELY 1400' | | FROM THE INTERCOASTAL. ON WHAT INFORMATION DID THE | | CONTRACTOR BASE THAT STATEMENT? PLEASE PROVIDE EVIDENCE | | OF EXPOSURE B CONDITIONS OR REVISE INSTALLATION | | SCHEDULE FOR EXPOSURE C. | | | | 2. OPENING 3 STATES THAT IT WILL BE INSTALLED | | HORIZONTALLY, THE HORIZONTAL DIMENSION (WXH) IS 95", | | BUT THE SPAN IS 40"? INFORMATION IS NOT CONSISTENT. | | THIS COMMENT APPLIES TO OTHER OPENINGS. | | | | 3. SEE OPENINGS 1 AND 2, HOW CAN THE SPAN BE THE SAME | | AS THE OPENING SIZE WITH A WALL MOUNT AND A .75 EDGE | | DISTANCE? PLEASE EITHER EXPLAIN OR REVISE. |
|