2009-05-15 16:34:42 | BUILDING PLAN REVIEW |
| PERMIT: 09050066 |
| ADD: 953 43RD ST |
| CONT: GREY CONSTRUCTION |
| TEL: (561-312-2766 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW |
| ACTION: DENIED |
| |
| 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| BUILDING WITH THE 2007 SUPPLEMENTS, AND THE 2007 |
| EXISTING BUILDING CODE WITH 2009 SUPPLEMENTS. PLEASE |
| UPDATE PLANS AND ALSO CHOOSE LEVEL OF ALTERATION. |
| EXISTING BUILDING CODE. 401.4 A DESIGN PROFESSIONAL OR |
| AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF |
| ALTERATION PURSUANT TO SECTIONS 403, 404 AND 405 OF |
| THIS CODE. |
| |
| 2) PLANS ARE MISSING THE WIND INFORMATION: 2007 |
| EXISTING BUILDING CODE, 606.4 REPLACEMENT OF WINDOWS |
| AND DOORS. THE REPLACEMENT OF GARAGE DOORS, EXTERIOR |
| DOORS, SKYLIGHTS, OPERATIVE AND INOPERATIVE WINDOWS |
| SHALL BE DESIGNED AND CONSTRUCTED TO COMPLY WITH |
| CHAPTER 16 OF THE FLORIDA BUILDING CODE, BUILDING . |
| |
| 1603.1.4 WIND DESIGN DATA. |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| BUILDING: |
| 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| (KM/HR). |
| |
| 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| |
| 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| DIRECTION SHALL BE INDICATED. |
| |
| 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION |
| OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| PROFESSIONAL. |
| |
| 3) THE PLAN SUBMITTED FOR WINDOW REPLACEMENT IS NOT |
| DRAWN TO SCALE IT CAN NOT BE DETERMINED WHICH WINDOWS |
| ARE IN THE END ZONES AND WHICH ARE LOCATED WITH-IN THE |
| INTERIOR ZONES, UNABLE TO DETERMINE PRESSURES. |
| |
| 4) THE WINDOW FLOOR PLAN ALSO IS MISSING WINDOW SIZES, |
| PLEASE PROVIDE WINDOW SIZES SO WINDOW OPENINGS CAN BE |
| REVIEWED FOR THE ASSOCIATED PRESSURES. NOTE: EXISTING |
| BUILDING CODE DOES ALLOW FOR A 5% REDUCTION IN CLEAR |
| OPENING DIMENSIONS FOR THE REPLACEMENT OF WINDOWS SHALL |
| BE ALLOWED. |
| |
| 5) THE PERMIT APPLICATION INDICATES A VALUE OF |
| $2,300.00 DOLLARS OF VALUE FOR PLUMBING, ELECTRICAL AND |
| REPLACEMENT OF 9 WINDOWS, WHERE AS ON THE WINDOW PLAN |
| THE VALUE ALONE FOR THE WINDOWS IS INDICATED AS $365.00 |
| EACH FOR A TOTAL OF $3,285.99. IT APPEARS THESE TWO |
| FIGURESTHE PLUMBING /ELECTRIC AND WINDOWS SHOULD BE |
| ADDED TOGETHER. |
| |
| W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES. |
| ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL, |
| AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT, |
| A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN |
| ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE |
| APPLICABLE GOVERNING AUTHORITY. |
| |
| 108.3* BUILDING PERMIT VALUATION. |
| IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| JIM WITMER C. B. O. |
| BUILDING PLAN REVIEW II |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |