2009-05-05 16:20:51DENIED
 REFERENCE:
 FBC-2007 W 2009 SUPPLEMENTS
 FBC-2007 EXISING BUILDING
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
  
 1. APPLICATIONS FOR PERMIT SUBMITTED ON OR AFTER MARCH
 1, 2009 SHALL BE DESIGNED UNDER THE FBC-2007 CODE
 CYCLE. PLEASE INDICATE ON THE PLANS THE PRESENT CODE
 CYCLE. SECTION 106.1.1.
  
 2. PLEASE INDICATE THE OCCUPANCY ON THE PLANS. SECTION
 106.3.5.1.1(2).
  
 3. A DESIGN PROFESSIONAL OR ON OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THE EXISTING BUILDING
 CODE. SECTION 401.4. PLEASE INDICATE ON PLANS.
  
 4. MORE INFORMATION IS REQUIRED ON THE LAUNDRY ROOM.
 SECTION 106.1.2. IS THE LAUNDRY ROOM FOR UNIT ONE ONLY?
 IF NOT A FLOOR DRAIN IS REQUIRED PER SECTION 412.4 OF
 THE PLUMBING CODE. PLEASE CLARIFY.
  
 5. THE SANITARY RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN. SEE THE RED LINE CORRECTION OF THE SANITARY
 RISER DIAGRAM SUBMITTED AS AN EXAMPLE AS A RISER THAT
 REFLECTS THE FLOOR PLAN. SECTION 106.1.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.