2009-04-22 13:47:53BUILDING PLAN REVIEW
 PERMIT: 09040291
 ADD: 4 HARVARD CIRCLE
 CONT: FISHER CONTRACTING CORP
 TEL: (561)691-4716
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
  
 * WEST PALM BEACH AMENDMENTS
  
 APRIL 22/2009
 1ST REVIEW
 ACTION: DENIED
  
 1A) : WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1B) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1C) : PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH THE 20097 SUPPLEMENTS.PLEASE REVISE COVER
 SHEET AND A120.1.
  
 2) SHEET A120.1 INDICATES (3) NEW OFFICES, THE NEW
 DOORS FAIL TO PROVIDE 18" ON THE PULL SIDE OF THE LATCH
 PLEASE REVIEW 11-4. 13.6.
 11-4.13.6 MANEUVERING CLEARENCES AT DOORS. MINIMUM
 MANEUVERING CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC
 OR POWER-ASSISTED SHALL BE AS SHOWN IN
 FIG. 25. THE FLOOR OR GROUND AREA WITHIN THE REQUIRED
 CLEARANCES SHALL BE CLEAR & LEVEL.
  
 3) NEW HANDICAPPED RESTROOM SHOWN ON A120.1 DOES NOT
 INDICATE ON SHEET A130.1 THAT THIS RESTROOM IS A
 HANDICAPPED RESTROOM, PLEASE INDICATE AS SUCH. SHEET
 A110.1 INDICATES THE REMOVAL OF SINK AND CABINET
 INACTING DISPROPORTIONATE COST SECTION 11-4.1.6 (2)(A)
 (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR
 A SINGLE UNISEX RESTROOM.
  
 3A) SHEET A120.1 INDICATES THE REQUIRED FLOOR SPACE FOR
 THE LAV AND WATER CLOSET. THE PLANS CLEARLY INDICATE
 THE DOOR SWINGING INTO THE REQUIRED CLEAR FLOOR SPACE.
 1-4.22.2 DOORS.(1) ALL DOORS TO ACCESSIBLE TOILET ROOMS
 SHALL COMPLY WITH SECTION 11-4.13. DOORS SHALL NOT
 SWING INTO THE CLEAR FLOOR SPACE REQUIRED FOR ANY
 FIXTURE.
  
 3B) SHEET A500.1 INDICATES THE E3 DOOR THAT LEADS TO
 THE NEW HANDICAPPED RESTROOM TO BE A 32 INCH DOOR
 CREATING A 30 INCH OPENING.
 11-4.13.5 DOORWAY MIN CLEAR WIDTH . DOORWAYS SHALL HAVE
 A MINIMUM CLEAR WIDTH OF 32" WITH THE DOOR OPEN
 90-DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND
 OPPOSITE STOP.
 NOTE THIS IS WHERE THE DISPROPORTIONATE COST REQUIRING
 A HANDICAPPED RESTROOM AND THE REMOVAL OF THE LAV AND
 CABINET CREATE THE REQUIREMENT FOR THE WIDER DOOR. ALSO
 NOTE THE LARGER DOOR WOULD ALSO SWING INTO THE CLEAR
 FLOOR SPACE REQUIRED FOR THE LAV AND WATER CLOSET.
  
 4) SHEET A130.1 DOOR# 2 TO THE RECEPTION AREA INDICATES
 A NEW GLASS SIDE LIGHT, THE DOOR SCHEDULE NOR IS IT
 PICKED UP WITH THE DETAIL 4/ A130.1 THIS REQUIRES
 SAFETY GLAZING. 2406.3(6).
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved