2009-04-27 13:49:17BUILDING PLAN REVIEW
 PERMIT: 09040206
 ADD: 8397 NICHOLLS POINT/ ANDOS ISLES
 CONT: NATIONWIDE POOLS
 TEL: (954)227-7665
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE/ RESIDENTIAL W/
 2009 FBC SUPPLEMENTS
  
 ****BUILDING PROVISO****:
  
 POOL PLAN INDICATES ???POOL ENCLOSURE,??? FENCE BY
 OWNERS, WILL REQUIRE A SEPARATE PERMIT.
  
 R4101.19 FINAL INSPECTION. FINAL ELECTRICAL, AND
 BARRIER CODE, INSPECTION SHALL BE COMPLETED PRIOR TO
 FILLING THE POOL WITH WATER.
  
 R4101.17.1.15A MESH SAFETY BARRIER MEETING THE
 REQUIREMENTS OF SECTION R4101.17 AND THE FOLLOWING
 MINIMUM REQUIREMENTS SHALL BE CONSIDERED A BARRIER AS
 DEFINED IN THIS SECTION:
  
 1.INDIVIDUAL COMPONENT VERTICAL SUPPORT POSTS SHALL BE
 CAPABLE OF RESISTING A MINIMUM OF 52 POUNDS (229 N) OF
 HORIZONTAL FORCE PRIOR TO BREAKAGE WHEN MEASURED AT A
 36-INCH (914 MM) HEIGHT ABOVE GRADE. VERTICAL POSTS OF
 THE CHILD MESH SAFETY BARRIER SHALL EXTEND A MINIMUM OF
 3 INCHES (76 MM) BELOW DECK LEVEL AND SHALL BE SPACED
 NO GREATER THAN 36 INCHES (914 MM) APART.
  
 PLEASE INDICATE HOW THE VERTICAL POST WILL BE SUPPORTED
 WHERE IT APPEARS THAT THE POST WILL BE PLACED IN A
 GRASSED IN AREA. THE SECTION ABOVE INDICATES THE POST
 ARE TO BE PLACED A MINIMUM OF 3 INCHES (76 MM) BELOW
 DECK LEVEL AND WITHIN A SLEEVE. PLEASE INDICATE HOW
 COMPLIANCE WITH THE 52 POUND HORIZONTAL FORCE WILL BE
 MET.
  