Plan Review Notes
Plan Review Notes For Permit 09030085
Permit Number 09030085
Review Stop B
Sequence Number 2
Notes
Date Text
2009-03-16 08:32:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 PLEASE SEE COMMENT FROM REVIEW OF MASTER PERMIT;
 09010024, AND PREVIOUS ROOF PERMIT REVIEW:
  
  
 5. CONTRACTOR MUST SELECT AN APPROVED ASSEMBLY AND
 SPECIFY ENHANCED FASTENING.
  
 CONTRACTOR SUBMITTED NOA 060613.06 FOR THE FLAT DECK
 WITH THE MASTER PERMIT AND HIGHLIGHTED THE ASSEMBLY ON
 PAGE 12 (INSULATED DECK). THIS ASSEMBLY HAS A DESIGN
 PRESSURE LIMITATION OF -60PSF. SEE GENERAL LIMITATION
 #7 ON THE NOA, CALCULATIONS FOR ENHANCED FASTENING FOR
 PERIMETER AND CORNER ZONES ARE TO BE CALCULATED BY AN
 ARCHITECT, ENGINEER, OR REGISTERED ROOF CONSULTANT.
  
 DELEGATED ENGINEERING (ENHANCED FASTENING CALCULATIONS)
 ARE TO BE REVIEWED BY ENGINEER OF RECORD FAC61G15-31.
  
 2ND ROOF PERMIT REVIEW, ENGINEERING SPECIFYING ROOF
 PRESSURES WAS SUBMITTED AS WELL AS ROOF SHEATHING
 NAILING PATTERN. THIS SHOULD HAVE BEEN INCLUDED ON THE
 MASTER PERMIT; THIS DOES NOT ADDRESS THE COMMENT.
 CALCULATIONS IN ACCORDANCE WITH RAS117 FOR THE
 INSULATION BOARD IS REQUIRED. ZONES 2 AND 3 HAVE A
 DESIGN PRESSURE OF -79.2, BUT THE ASSEMBLY SELETED HAS
 A DESIGN PRESSURE LIMITATION OF -60PSF. ENHANCED
 FASTENING IN ACCORDANCE WITH RAS117 REQUIRED FOR THIS
 ASSEMBLY (-60PSF) TO MEET THE DESIGN PRESSURE (-79.2).
  
 SEE PAGE 20 OF THE NOA, ITEM 7:
  
 PERMIETER AND CORNER AREAS SHALL COMPLY WITH THE
 ENHANCED UPLIFT PRESSURE REQUIREMENTS OF THESE AREAS.
 FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION AND BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARD RAS 117. CALCULATIONS
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR
 REGISTERED ROOF CONSLUTANT.
  
 THE ENGINEERING SUBMITTED IS ENTITLED "ROOF AND WALL
 NAILING SCHEDULE." THIS IS ROOF SHEATHING NAILING
 SCHEDULE, NOT THE ROOF ASSEMBLY NAILING SCHEDULE. THIS
 APPLIES TO THE PLYWOOD INSTALLATION, NOT THE ROOF
 ASSEMBLY (TAMKO BUR ROOFING SYSTEM) INSTALLATION.
  
  
  