Plan Review Notes
Plan Review Notes For Permit 09020541
Permit Number 09020541
Review Stop B
Sequence Number 1
Notes
Date Text
2009-02-26 08:15:352004 FLORIDA BUILDING CODE &
 CITY OF WEST PALM BEACH AMENDMENTS TO THE 2004 FBC
 R-3 REROOF
  
 ****CORRECTIONS****
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 ____ 1.) EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER
 BARRIER REQUIRED FS553.844(5)(A). PROVIDE INFORMATION
 (PRODUCT APPROVAL OR SPECIFICATIONS) TO SHOW HOW YOU
 WILL COMPLY WITH THIS REQUIREMENT. INFORMATION IS
 AVAILABLE AT WWW.BOAF.NET, HURRICANE MITIGATION.
  
 __X__ 2.) CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION: AREA OF FLAT ROOF.
  
 ____ 3.) FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72. WWW.FLORIDABUILDING.ORG
  
 __X__ 4.) FOR THE FLAT ROOF, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING. ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 __X___ 5.) FOR THE FLAT ROOF, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES. THIS IS TO BE
 SUBMITTED ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE
 RESUB SHEET). SEE GENERAL LIMITATION #7 ON PAGE 19 OF
 NOA NO. 07-0111.03.
  
 ____ 6.) ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING. IF YOU SELECT FOAM
 ADHESIVE, PRODUCT APPROVALS REQUIRED FAC9B72.
  
 ____ 7.) SEE PRODUCT LIMITATION #7. CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
 ____ 8.) SUBMIT 2 COPIES OF THE PRODUCT APPROVALS. ONLY
 ONE WAS SUBMITTED.
  
 __X__ 9.) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 WILL BE REQUIRED.
  
 NOTE: DOUBLE UNDERLAYMENT REQUIRED FOR ASPHALT SHINGLES
 ON SLOPES LESS THAN 4:12 PER FBC R905.2.
  