Plan Review Notes
Plan Review Notes For Permit 09020471
Permit Number 09020471
Review Stop B
Sequence Number 2
Notes
Date Text
2009-04-30 09:42:52****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STA
  
 1-4. ADDRESSED.
  
 4. SHOW COMPLIANCE WITH FBC R704, INSPECTION FOR
 TERMITES.
  
 2ND REVIEW, DETAILS SHOW STUCCO EXTENDING TO GRADE.
 PLEASE SEE FBC R704 AND REVISE DETAIL ACCORDINGLY.
  
 5-6. ADDRESSED.
  
 7. ROOF PERMIT HAS BEEN APPLIED FOR. THEREFORE, ALL
 ROOF PERMIT INFORMATION REQUIRED AT THIS TIME:
  
 A. ADDRESSED.
  
 B. PROVIDE ENHANCED FASTENING PATTERN FOR PERIMETER AND
 CORNER ZONES
  
 2ND REVIEW, PLAN WAS REVISED TO STATE "FASTEN TO ALL
 SUPPORTS W/8D NAILS @ 6"EDGES, 6" FIELD." IT APPEARS
 THAT THIS IS INTENDED TO BE PLYWOOD SHEATHING
 FASTENING, BUT THIS DOES NOT COMPLY WITH FBC R
 803.2.3.1 ZONE 3. ADDITIONALLY, THIS DOES NOT ADDRESS
 THE COMMENT FOR THE ROOF. PLEASE SEE NOA, GENERAL
 LIMITATION #7 ON PAGE 19, ENHANCED FASTENING TO BE IN
 ACCORDANCE WITH RAS117 (ALSO NOTE THAT THERE ARE TWO
 DIFFERENT FASTENING OPTIONS; ENHANCED FASTENING SHOULD
 REFER TO WHICH OPTION IS PROPOSED IN ORDER TO DETERMINE
 CODE COMPLIANCE UNLESS THE PATTERN PROPOSED COMPLIES
 WITH BOTH). PLEASE NOTE THAT IF ALL REQUIRED
 INFORMATION IS NOT PROVIDED PRIOR TO ISSUANCE OF THE
 MASTER PERMIT, THE ROOF PERMIT WILL BE VOIDED AND A
 SEPARATE PERMIT WILL BE REQUIRED IN ORDER TO AVOID
 DELAYS ON THE MASTER PERMIT.
  
 8. ADDRESSED.
  
 9. FBC R403.1.4, SHOW DISTANCE OF BOTTOM OF FOOTING TO
 GRADE.
  
 2ND REVIEW, THIS IS SHOWN AS 10IN. SEE FBC R403.1.4,
 MINIMUM DEPTH REQUIRED IS 12IN.
  
 10-11. ADDRESSED.
  
 12. ROOF SHEATHING NAILING NOT COMPLIANT WITH FBC R
 803.2.3.1. SEE DETAILS 1 A3, 2 A3, CHECK ALL.
  
 2ND REVIEW, 4IN REQUIRED AT ZONE 3, SEE FBC R803.2.3.1.
  
 13-14. ADDRESSED.
  
 15. IMPACT FEES MAY BE DUE. PLEASE CONTACT PALM BEACH
 COUNTY, 233-5025.
  
 2ND REVIEW, THE PLANS MUST BE STAMPED AND THE RECEIPT
 (IF FEES ARE DUE) ATTACHED TO THE APPLICATION. THIS MAY
 BE DONE AFTER ALL PLAN REVIEWS ARE COMPLETED BUT MUST
 BE DONE PRIOR TO PERMIT ISSUANCE.
  
 16-17. ADDRESSED.
  
  