Date |
Text |
2009-02-19 12:04:47 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBC FLORIDA BUILDING CODE 2004 |
| FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| CODE |
| FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| FAC FLORIDA ADMINISTRATIVE CODE |
| FS FLORIDA STATUTE |
| |
| 1. SEE OPENING 8. CONNECTION TYPE A AND I REQUIRE A |
| CONCRETE SUBSTRATE, SEE PAGE 13. PLEASE CHECK ALL. IF |
| CONCRETE IS SPECIFIED AS A SUBSTRATE, EVIDENCE SHOWING |
| THAT THE EXISTING CONCRETE MEETS THE MINIMUM DESIGN |
| STRENGTH REQUIRED ON THE PRODUCT APPROVAL WILL BE |
| REQUIRED. |
| |
| 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, |
| FAC9B72. EVALUATION REPORTS WERE SUBMITTED WITHOUT THE |
| FLORIDA STATE PRODUCT APPROVAL COVER SHEETS. PLEASE |
| PROVIDE THIS TO SHOW COMPLIANCE WITH FAC9B72. THEY MAY |
| BE AVAILABLE AT WWW.FLORIDABUILDING.ORG. |
| |
| 3. SEE OPENING 9. SPECIFIC ANCHOR TYPE, ITW TAPCON |
| PROPOSED. SEE SHEET 10 OF THE PRODUCT APPROVAL, |
| MOUNTING TYPE 1 , TAPCON REQUIRES 7" SPACING FOR 3 1/2" |
| EDGE DISTANCE, REQUIRES A FACTOR. THE PRODUCT APPROVALS |
| ARE NOT LEGIBLE SO I CANNOT DETERMINE THE FACTOR |
| REQUIRED. |
| |
| 4. PLEASE PROVIDE LEGIBLE PRODUCT APPROVALS. FOR |
| INSTANCE, PAGE 10 HAS A PORTION OF THE SHEET CUT OFF. |
| THE FACTOR REQUIRED IS ILLEGIBLE, AND THE SPACING FOR |
| 12" CONNECTION TYPE 1 TO MASONRY IS DIFFICULT TO READ |
| AS IT APPEARS TO BE A PHOTOCOPY OF SOMETHING THAT HAD |
| BEEN OBSCURED BY HIGHLIGHTER. |
| |
| 5. SOME INFORMATION NOT PERTINENT TO THIS JOB HAS BEEN |
| HIGHLIGHTED. FOR INSTANCE, SHEET 10, 9" SPACING (TO |
| CONCRETE) HIGHLIGHTED. ALL INFORMATION WHICH IS EITHER |
| HIGHLIGHTED OR CIRCLED IS HELPFUL FOR INSPECTIONS BUT |
| SHOULD CORRELATE WITH THE INSTALLATION SCHEDULE AND |
| WITH THE JOB. |
| |
| 6. PLEASE CHECK ALL ANCHOR SPACING, CONNECTIONS, ETC. |
| ON THE PLAN. SOME COMMENTS MAY APPLY TO OTHER OPENINGS; |
| THE OPENING NUMBER IN THE COMMENT LIST MAY BE AN |
| EXAMPLE OF A NON COMPLIANT ITEM WHICH MAY APPLY TO |
| OTHER OPENINGS. |
| |
| |
| |