Plan Review Notes
Plan Review Notes For Permit 09020335
Permit Number 09020335
Review Stop B
Sequence Number 2
Notes
Date Text
2009-03-04 16:53:54****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1. SEE SHEET 8, CONCRETE ANCHOR SPACING CIRCLED BUT
 CONCRETE BLOCK SPECIFIED AS SUBSTRATE. PLEASE REVISE.
 FOR INSTANCE, OPENING 2 SHOULD HAVE ANCHOR SPACING OF 3
 1/2" TOP AND BOTTOM.
  
 2ND REVIEW, TOP WAS CHANGED BUT BOTTOM IS STILL 9".
  
 2. OPENINGS 8 THORUGH 11, CONCRETE SUBSTRATE SPECIFIED.
 DOESN'T THIS HOUSE HAVE A BOND BEAM RATHER THAN A TIE
 BEAM AT THE TOP? PROVIDE EVIDENCE THAT THE TOP AND
 BOTTOM ARE FORMED AND POURED CONCRETE.
  
 COMMENT NOT ADDRESSED. BOTTOM WAS CHANGED ON SOME, BUT
 TOP AND BOTTOM SHOULD HAVE SAME ANCHOR SPACING AS THEY
 HAVE SAME SPAN, SAME SUBSTRATE.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved