2009-02-24 09:29:23****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. SEE SHEET 8, CONCRETE ANCHOR SPACING CIRCLED BUT
 CONCRETE BLOCK SPECIFIED AS SUBSTRATE. PLEASE REVISE.
 FOR INSTANCE, OPENING 2 SHOULD HAVE ANCHOR SPACING OF 3
 1/2" TOP AND BOTTOM.
  
 2. OPENINGS 8 THORUGH 11, CONCRETE SUBSTRATE SPECIFIED.
 DOESN'T THIS HOUSE HAVE A BOND BEAM RATHER THAN A TIE
 BEAM AT THE TOP? PROVIDE EVIDENCE THAT THE TOP AND
 BOTTOM ARE FORMED AND POURED CONCRETE.