2009-04-08 12:44:30PROVISO;
 PROVIDE ROOF SYSTEM AS STATED ON SHEET A3; ROOF PRODUCT
 APPROVAL FL# 10264-RO(PAGE 2 OF 9); ROOFING MEMBRAINE:
 FIRESTONE ULTRAPLY TPO 60 MIL: FIRESTONE ISO 95 T GL
 INSULATION 3.5" TOTAL THICKNESS: R-VALUE 21.7;
 PROTECTION BOARD DENS-DECK PRIME 1/2" MIN: SYSTEM TYPE
 C SYSTEM NO. SC-4(ZONE 1&2) SC-7(ZONE 3): MAXIMUM
 DESIGN PRESSURE SC-4 (-75.0 PSF) SC-7 (-105 PSF). THIS
 INFORMATION SHALL BE SUBMITTED BY THE ROOFING
 CONTRACTOR PRIOR TO INSTALLATION. ALSO SUBMIT A LAYOUT
 OF THEROOF INSULATION PRIOR TO INSTALLATION.
  
 PROVIDE ADDITIONAL INFORMATION/ SIGN AND SEAL DOCUMENTS
 FROM A FLORIDA DESIGN PROFESSIONAL SHOWING HOW THE ROOF
 TOP UNITS WILL REMAIN IN PLACE DURING PERIODS OF HIGH
 WINDS.