Plan Review Notes For Permit 09010489 |
Permit Number |
09010489 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2009-02-19 12:00:33 | 2004 FBC W/2007 REVISIONS | | ENCLOSE COVERED PATIO | | | | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | BE REQUIRED. FS 713 | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. PHONE (561) | | 233-5025 | | | | 3) THE EXPOSURE CATEGORY IS INCORRECTLY SPECIFIED AS | | 'B' ON THE PLANS. PLEASE REVISE TO EXPOSURE CATEGORY | | 'C' . FBC R301.2.1.4 (3) EXPOSURE C. OPEN TERRAIN WITH | | SCATTERED OBSTRUCTIONS, INCLUDING SURFACE UNDULATIONS | | OR OTHER IRREGULARITIES, HAVING HEIGHTS GENERALLY LESS | | THAN 30 FEET (9144 MM) EXTENDING MORE THAN 1,500 FEET | | (456 M) FROM THE BUILDING SITE IN ANY QUADRANT. THIS | | EXPOSURE SHALL ALSO APPLY TO ANY BUILDING LOCATED | | WITHIN EXPOSURE B-TYPE TERRAIN WHERE THE BUILDING IS | | DIRECTLY ADJACENT TO OPEN AREAS OF EXPOSURE C-TYPE | | TERRAIN IN ANY QUADRANT FOR A DISTANCE OF MORE THAN 600 | | FEET (182.9 M). | | | | 4) PLEASE REVISE OPENING PRESSURES SPECIFIED ON THE | | PLANS FOR THE SLIDING GLASS DOORS TO COORDINATE WITH | | EXPOSURE C. TABLE R301.2(3) | | | | 5) SUBMIT ENERGY CALCULATIONS AS REQUIRED BY FBC | | 13-101.2.2. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|