Plan Review Notes For Permit 09010455 |
Permit Number |
09010455 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2009-02-02 10:15:54 | 2004 FBC W/2007 REVISIONS | | REPLACE ROOF FRAMING | | | | DENIED BY BUILDING | | | | 1) THE TRUSS DRAWINGS THAT WERE SUBMITTED SPECIFY FOUR | | BEARING POINTS FOR THE T-1 TRUSSES. THE ARCHITECTURAL | | DRAWINGS DO NOT SPECIFY TRUSS ANCHORS AT THE TWO | | INTERIOR BEARING WALLS. PLEASE CORRECT. FBC 2319.17.2 | | | | 2) THE TRUSS DRAWING AND LAYOUT SPECIFIES FOUR TRUSSES | | SET AWAY FROM THE RAKE BEAM END WALLS. PROVIDE A DETAIL | | OF THE STRUCTURAL ROOF TO RAKE BEAM ATTACHMENTS AT BOTH | | ENDS. SHOW THE FRAMING THAT WILL SUPPORT THE ROOF | | SHEATHING AND DRYWALL AT THE WALLS. FBC 2304.1 | | | | 3) THE VALUE FOR THE WORK SPECIFIED ON THE APPLICATION | | APPEARS TO BE LOW FOR THE SCOPE OF WORK. THE VALUE OF | | WORK IS TO INCLUDE ALL LABOR, MATERIAL, DESIGN, | | OVERHEAD AND PROFIT. PLEASE REVISE VALUE ACCORDINGLY. | | FBC* 108.3 CITY AMENDMENTS. | | | | 4) HAVE THE DESIGNER OF RECORD REVIEW AND APPROVE THE | | TRUSS LAYOUT IN WRITING. A SHOP DRAWING REVIEW STAMP IS | | ACCEPTABLE. FBC 2319.17.2.1.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|